Your browser doesn't support javascript.
loading
Ultra-low radiation dose and contrast volume CT protocol and TAVI-CT score for TAVI planning and outcome.
Fogante, Marco; Esposto Pirani, Paolo; Cela, Fatjon; Balardi, Liliana; Piva, Tommaso; Argalia, Giulio; Schicchi, Nicolò.
Afiliación
  • Fogante M; SOD di Radiologia Materno-Infantile, Senologica, Cardiologica ed Ecografia Ambulatoriale, University Hospital of Marche, Ancona, Italy.
  • Esposto Pirani P; SOD di Radiologia Materno-Infantile, Senologica, Cardiologica ed Ecografia Ambulatoriale, University Hospital of Marche, Ancona, Italy.
  • Cela F; SOD di Radiologia Materno-Infantile, Senologica, Cardiologica ed Ecografia Ambulatoriale, University Hospital of Marche, Ancona, Italy.
  • Balardi L; Direzione Aziendale, University Hospital of Marche, Ancona, Italy.
  • Piva T; SOD Cardiologia Ospedaliera e UTIC, University Hospital of Marche, Ancona, Italy.
  • Argalia G; SOD di Radiologia Materno-Infantile, Senologica, Cardiologica ed Ecografia Ambulatoriale, University Hospital of Marche, Ancona, Italy.
  • Schicchi N; SOS Diagnostica Radiologica Cardiovascolare - University Hospital of Marche, Ancona, Italy.
Br J Radiol ; 96(1148): 20221026, 2023 Aug.
Article en En | MEDLINE | ID: mdl-37183830
ABSTRACT

OBJECTIVE:

To investigate the feasibility of an ultra-low radiation dose and contrast volume protocol using third-generation dual-source (DS) CT for transcatheter aortic valve implantation (TAVI) planning with coronary artery disease (CAD) assessment, coronary artery calcium score (CACS) and aortic valve calcium score (AVCS) quantification and to evaluate their relationship with TAVI outcome.

METHODS:

In this retrospective study were selected 203 patients (131 males, 79.4 ± 5.4 years) underwent to TAVI and at 30- and 90-day follow-up. All patients had performed a third-generation 2 × 192-slices DSCT. The CT protocol included a non-contrast and a contrast high-pitch aortic acquisition for TAVI planning and CAD assessment. Semi-qualitative and quantitative image analysis were performed; the performance in CAD assessment was compared with ICA; the relationship between AVCS and CACS and paravalvular aortic regurgitation (PAR) and major cardiovascular events (MACEs) were evaluated. Mean radiation dose were calculated. Non-parametric tests were used.

RESULTS:

Semi-qualitative image analysis was good. Contrast enhancement >500 Hounsfield unit (HU) and contrast-to-noise ratio <20 were obtained in all segments. The diagnostic accuracy in CAD was 89.0%. AVCS was significantly higher in patients with 30-day severe PAR. AVCS and CACS were higher in patients with 90-day MACE complications, respectively, 1904.5 ± 621.3 HU (p < 0.0001) and 769.2 ± 365.5 HU (p < 0.0230). Mean radiation dose was 2.8 ± 0.3 mSv.

CONCLUSION:

A TAVI planning ultra-low radiation dose and contrast volume protocol using third-generation DSCT provides highly diagnostic images with CAD assessment, AVCS and CACS quantification and these latter were related with TAVI outcomes. ADVANCES IN KNOWLEDGE The proposed protocol using third-generation 2 × 192-slices DSCT allows with an ultra-low radiation dose and contrast volume the TAVI planning and the coronary artery assessment.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Enfermedad de la Arteria Coronaria / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Guideline / Observational_studies / Qualitative_research Límite: Humans / Male Idioma: En Revista: Br J Radiol Año: 2023 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Enfermedad de la Arteria Coronaria / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Guideline / Observational_studies / Qualitative_research Límite: Humans / Male Idioma: En Revista: Br J Radiol Año: 2023 Tipo del documento: Article País de afiliación: Italia