Combination of Laser Atherectomy and Super High-pressure Non-compliant Balloon to Treat Stent Under-expansion in Cases of Failed Interventional Options.
Sasi, Viktor; Szántó, Gyula; Achim, Alexandru; Ungi, Imre; Varga, Albert; Ruzsa, Zoltán.
Afiliación
  • Sasi V; Department of Internal Medicine, Medical Faculty, Division of Invasive Cardiology, Hungary Albert Szent-Györgyi Clinical Center, University of Szeged Szeged, Hungary.
  • Szántó G; Department of Internal Medicine, Medical Faculty, Division of Invasive Cardiology, Hungary Albert Szent-Györgyi Clinical Center, University of Szeged Szeged, Hungary.
  • Achim A; Department of Interventional Cardiology, Medicala 1 Clinic, Iuliu Hațieganu University of Medicine and Pharmacy Cluj-Napoca, Romania.
  • Ungi I; Klinik für Kardiologie, Medizinische Universitätsklinik, Kantonsspital Baselland Liestal, Switzerland.
  • Varga A; Department of Internal Medicine, Medical Faculty, Division of Invasive Cardiology, Hungary Albert Szent-Györgyi Clinical Center, University of Szeged Szeged, Hungary.
  • Ruzsa Z; Department of Internal Medicine, Medical Faculty, Division of Invasive Cardiology, Hungary Albert Szent-Györgyi Clinical Center, University of Szeged Szeged, Hungary.
Interv Cardiol ; 18: e23, 2023.
Article en En | MEDLINE | ID: mdl-37538386
Patients with calcified, fibrotic native coronary vessels with prior suboptimal stenting outcomes are at major risk of stent thrombosis and could face serious consequences if untreated. In cases of multiple layers of under-expanded stents, the risk is multiplied. If conventional balloon post-dilatation is unsuccessful after stent implantation without proper lesion preparation, few interventional options remain. The authors report on a patient with prior numerous right coronary unsuccessful coronary interventions resulting in partially crushed multiple layers of stent material with critical lumen narrowing caused by stent under-expansion. Balloon angioplasty and stent rotational atherectomy (ROTA) had been attempted to overcome stent under-expansion but were unsuccessful. The authors investigated a new combination therapy of laser atherectomy (ELCA) and super high-pressure balloon (OPN non-compliant balloon) to treat single or multiple layers of stent with severe under-expansion due to fibrotic, calcified tissue surrounding the under-expanded stent structure.