Improving regional medical laboratory center report quality through a report recall management system.
Clin Chem Lab Med
; 62(2): 341-352, 2024 Jan 26.
Article
en En
| MEDLINE
| ID: mdl-37673465
OBJECTIVES: Currently, most medical laboratories do not have a dedicated software for managing report recalls, and relying on traditional manual methods or laboratory information system (LIS) to record recall data is no longer sufficient to meet the quality management requirements in the large regional laboratory center. The purpose of this article was to describe the research process and preliminary evaluation results of integrating the Medical Laboratory Electronic Record System (electronic record system) laboratory report recall function into the iLab intelligent management system for quality indicators (iLab system), and to introduce the workflow and methods of laboratory report recall management in our laboratory. METHODS: This study employed cluster analysis to extract commonly used recall reasons from laboratory report recall records in the electronic record system. The identified recall reasons were validated for their applicability through a survey questionnaire and then incorporated into the LIS for selecting recall reasons during report recall. The statistical functionality of the iLab system was utilized to investigate the proportion of reports using the selected recall reasons among the total number of reports, and to perform visual analysis of the recall data. Additionally, we employed P-Chart to establish quality targets and developed a "continuous improvement process" electronic flow form. RESULTS: The reasons for the recall of laboratory reports recorded in the electronic recording system were analyzed. After considering the opinions of medical laboratory personnel, a total of 12 recall reasons were identified, covering 73.05â¯% (1854/2538) of the recalled laboratory reports. After removing data of mass spectra lab with significant anomalies, the coverage rate increased to 82.66â¯% (1849/2237). The iLab system can generate six types of statistical graphs based on user needs, including statistical time, specialty labs (or divisions), test items, reviewers, reasons for report recalls, and distribution of the recall frequency of 0-24 h reports. The control upper limit of the recall rate of P-Chart based on laboratory reports can provide quality targets suitable for each professional group at the current stage. Setting the five stages of continuous process improvement reasonably and rigorously can effectively achieve the goal of quality enhancement. CONCLUSIONS: The enhanced iLab system enhances the intelligence and sustainable improvement capability of the recall management of laboratory reports, thus improving the efficiency of the recall management process and reducing the workload of laboratory personnel.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Sistemas de Información en Laboratorio Clínico
/
Registros Electrónicos de Salud
Límite:
Humans
Idioma:
En
Revista:
Clin Chem Lab Med
Asunto de la revista:
QUIMICA CLINICA
/
TECNICAS E PROCEDIMENTOS DE LABORATORIO
Año:
2024
Tipo del documento:
Article