Your browser doesn't support javascript.
loading
Real-time loop-mediated isothermal amplification (real-time LAMP) assay for rapid diagnosis of amoebic liver abscess.
Khunger, Sandhya; Mewara, Abhishek; Kaur, Upninder; Duseja, Ajay; Ray, Pallab; Kalra, Naveen; Sharma, Navneet; Sehgal, Rakesh.
Afiliación
  • Khunger S; Department of Medical Parasitology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Mewara A; Department of Microbiology(FAHS), Shree Guru Gobind Singh Tricentanary University, Gurugram, India.
  • Kaur U; Department of Medical Parasitology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Duseja A; Department of Medical Parasitology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Ray P; Department of Hepatology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Kalra N; Department of Medical Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Sharma N; Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Sehgal R; Department of Internal Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Trop Med Int Health ; 29(2): 104-112, 2024 02.
Article en En | MEDLINE | ID: mdl-38093589
Among the parasitic diseases, amoebic liver abscess (ALA) ranks second to malaria in terms of mortality. Due to the poor sensitivity of conventional diagnostic methods, there is a need for the development of effective and rapid diagnostic methods for ALA. Thus, the purpose of this work was to develop a real-time loop-mediated isothermal amplification (RT-LAMP) assay specific to Entamoeba histolytica. Further, we compared the performance of real-time LAMP with conventional and real-time PCR (RT-PCR) targeting 18S small subunit ribosomal RNA (18S SSU rRNA) gene of E. histolytica in patients with ALA. A total of 126 liver samples were obtained for the study. Of these, 96 aspirated pus samples were obtained from patients suffering from an ALA (serology confirmed, anti-amoebic immunoglobulin IgG positive), 19 aspirated pus samples from patients with pyogenic liver abscess (PLA, 16S RNA gene positive) and 11 autopsy liver tissues. The results showed that the DNA of E. histolytica was detected in 81 samples by conventional PCR, 93 by RT-PCR and 95 by RT-LAMP. The analytical sensitivity of the RT-LAMP assay was much higher than the other two techniques. RT-LAMP assay was able to amplify up to one copy of the targeted gene of E. histolytica while conventional PCR and RT-PCR could amplify up to 103 and 102 copies of the targeted gene of E. histolytica, respectively. In conclusion, RT-LAMP proved to be a sensitive, specific and rapid test which can be utilised as an effective tool for the diagnosis of ALA.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Absceso Hepático Amebiano Límite: Humans Idioma: En Revista: Trop Med Int Health Asunto de la revista: MEDICINA TROPICAL / SAUDE PUBLICA Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Absceso Hepático Amebiano Límite: Humans Idioma: En Revista: Trop Med Int Health Asunto de la revista: MEDICINA TROPICAL / SAUDE PUBLICA Año: 2024 Tipo del documento: Article País de afiliación: India