Your browser doesn't support javascript.
loading
Comparative Assessment of Three Different Alveolar Ridge Dimension Measurement Methods before Implant Placement: An In Vivo Study.
Das, Asutosh; Vijayakumar, Deepa Basapur; Sathe, Saurabh; Sapri, Ahmed Mohammed Saaduddin; Thomas, Pallavi Ammu; Kappiamkunnath, Sarath; Singh, Praveen Kumar.
Afiliación
  • Das A; Department of Oral and Maxillofacial Surgery, Kalinga Institute of Dental Sciences, Kalinga Institute of Technology (Deemed to be University), Bhubaneswar, Odisha, India.
  • Vijayakumar DB; Department of Oral and Maxillofacial Surgery, JSS Dental College and Hospital, JSS Academy of Higher Education & Research (JSSAHER), Mysuru, Karnataka, India, Phone: +91 8892706015, e-mail: drdeepabv@gmail.com.
  • Sathe S; Department of Oral and Maxillofacial Surgery, Bhabha College of Dental Sciences, Bhopal, Madhya Pradesh, India.
  • Sapri AMS; Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Mansoura University, Egypt.
  • Thomas PA; Department of Public Health Dentistry, Al Azhar Dental College, Thodupuzha, Kerala, India.
  • Kappiamkunnath S; Department of Oral and Maxillofacial Surgery, Mahe Institute of Dental Sciences & Hospital, Mahé, Puducherry, India.
  • Singh PK; Department of Oral and Maxillofacial Surgery, Chandra Dental College and Hospital, Lucknow, Uttar Pradesh, India.
J Contemp Dent Pract ; 24(9): 651-654, 2023 Sep 01.
Article en En | MEDLINE | ID: mdl-38152937
ABSTRACT

AIM:

The purpose of this study was to compare the three various techniques for measuring the alveolar ridge's dimensions prior to implant insertion. MATERIALS AND

METHODS:

For this study, a total of 36 participants were chosen. To prepare a surgical stent, a study model was created from an alginate impression. A first point (reference point) was marked on the crest of the ridge in relation to the adjacent teeth. Then, one point (point 1) and another point (point 2) were marked at distances of 3 and 6 mm, respectively, from the reference point. Based on the procedure for measuring the size of the alveolar ridge, the study was divided into the following groups. Group I Cone-beam computed tomography (CBCT) measurement method; Group II Ridge mapping measurement method; Group III Direct caliper measurements method. Descriptive statistics were used to estimate the mean and standard deviation (SD). The Student's unpaired t-test was utilized for the statistical analysis. The 5% level of significance was used.

RESULTS:

There was no significant difference found between CBCT with ridge mapping and direct caliper measurements. However, on comparison of ridge mapping and direct caliper measurements technique, at point 1, the ridge mapping was 3.88 ± 0.12 and the direct caliper measurement was 3.62 ± 0.08. At point 2, the ridge mapping was 6.58 ± 0.06 and the direct caliper measurement was 6.32 ± 0.04. There was a statistically significant difference found between these two measurement methods.

CONCLUSION:

Within the limitation, the current study came to the conclusion that when CBCT and ridge mapping measurements were individually compared with the gold standard-the surgical open method, CBCT-demonstrated to be a highly specific and sensitive method for detecting the residual alveolar ridge width in the treatment planning of dental implants. CLINICAL

SIGNIFICANCE:

Evaluation of alveolar bone is necessary during treatment planning for dental implant placement. Using simply panoramic and/or periapical radiographs to evaluate the bone may not be sufficient because it only provides two-dimensional information regarding the implant locations. Therefore, for better implant placement, three-dimensional information of the implant site, such as CBCT and ridge mapping technique, should be assessed.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diente / Proceso Alveolar Límite: Humans Idioma: En Revista: J Contemp Dent Pract / J. contemp. dent. pract / The journal of contemporary dental practice Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Diente / Proceso Alveolar Límite: Humans Idioma: En Revista: J Contemp Dent Pract / J. contemp. dent. pract / The journal of contemporary dental practice Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: India