Tian, Linhua; Nelson, Aaron R; Lowe, Tyler; Weaver, Linda; Yuan, Constance; Wang, Hao-Wei; DeRose, Paul; Stetler-Stevenson, Maryalice; Wang, Lili.
Afiliación
  • Tian L; Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, USA.
  • Nelson AR; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Lowe T; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Weaver L; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Yuan C; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Wang HW; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • DeRose P; Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, USA.
  • Stetler-Stevenson M; Laboratory of Pathology, National Cancer Institute, National Institutes of Health, Bethesda, Maryland, USA.
  • Wang L; Biosystems and Biomaterials Division, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, USA.
Cytometry B Clin Cytom ; 106(1): 25-34, 2024 01.
Article en En | MEDLINE | ID: mdl-38217297
ABSTRACT
Since response to antigen-based immunotherapy relies upon the level of tumor antigen expression we developed an antigen quantification assay using ABC values. Antigen quantification as a clinical assay requires methods for quality control and for interlaboratory and inter-cytometer platform standardization. A single lot of Cytotrol™ Lyophilized Control Cells (Beckman Coulter) used for all studies. The variability in antigen quantification across 4 different instrument platforms in 2 separate laboratories was evaluated. The effect of the antibody clone utilized, importance of custom 11 molar ratio (fluorophore to protein, F/P) verses off-the-shelf antibodies, and QuantiBrite PE calibration verses linearity calibration combined with a single point scale transformation with CD4 as reference were determined. Use of single lot control cells allowed validation of reproducibility between flow cytometer platforms and laboratories and allowed assessment of different antibody lots, cocktail preparation, and different antibody clones. Off the shelf antibody preparations provide reproducible estimates of antigen density, however custom 11 unimolar antibody preparations should be utilized for definitive measurement of antigen expression.Geometric Mean fluorescent Intensity (GeoMFI) was not comparable across instruments and inter-laboratory. The use of CD4 as the reference marker can minimize variability in ABC values. Comparable antigen quantification is vital in managing patients receiving antigen-based immunotherapy. If this assay is to be utilized in a clinical setting, quality control methods have to be instituted to assure reproducibility and allow validation across laboratories. We have demonstrated that use of a lyophilized cell control is highly valuable in achieveing these goals.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Anticuerpos / Antígenos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Cytometry B Clin Cytom Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Anticuerpos / Antígenos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Cytometry B Clin Cytom Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos