Your browser doesn't support javascript.
loading
Determination of phosphate in food based on molybdenum yellow derivatization coupled with resonance Rayleigh scattering method.
Li, Li; Zhang, Jiahua; Deng, Zhichen; Su, Zhengquan; Bai, Yan; He, Jincan.
Afiliación
  • Li L; School of Public Health, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, China.
  • Zhang J; School of Public Health, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, China.
  • Deng Z; School of Public Health, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, China.
  • Su Z; Guangdong Engineering Research Center of Natural Products and New Drugs, Guangdong Provincial University Engineering Technology Research Center of Natural Products and Drugs, Guangdong Pharmaceutical University, Guangzhou, 510006, China.
  • Bai Y; School of Public Health, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, China. angell_bai@163.com.
  • He J; School of Public Health, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, China. hejincan300@163.com.
Anal Sci ; 40(3): 461-469, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38236492
ABSTRACT
This paper proposed a rapid, selective and sensitive molybdenum yellow derivatization coupled with Resonance Rayleigh scattering (MYD-RRS) method for detection of phosphate. Under the acidic condition, phosphate can be selectively transformed to Keggin type of phosphomolybdic acid (PMA, i.e., PMo12O403-) through molybdenum yellow derivatization reaction prior to RRS detection. The PMA can further react with cationic methyl violet (MV) to form larger PMA-MV ion association complexes, generating significant RRS signal. The concentration of phosphate was linearly related to the RRS signal in the range of 8-200 ng/mL, with the determining coefficient (R2) of 0.9973 and the detection limit of 4 ng/mL. The analytical procedure can be completed within 10 min and the RRS signal intensity can remain stable more than 4 h. The method showed good stability toward temperature and time, and good anti-interference capability. The method was applied to the determination of phosphate in real food samples with the recovery of 85-117% and RSD of 1-5.2%. With the advantages of rapidness, high sensitivity and good selectivity, the MYD-RRS method exhibits great potential to the determination of phosphate in food. It also provides an instructive strategy for detection of analytes with weak RRS signal.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fosfatos / Molibdeno Idioma: En Revista: Anal Sci Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fosfatos / Molibdeno Idioma: En Revista: Anal Sci Año: 2024 Tipo del documento: Article País de afiliación: China