Your browser doesn't support javascript.
loading
Hepatopulmonary Shunt Ratio Verification Model for Transarterial Radioembolization.
Yeyin, Nami; Kesmezacar, Fahrettin Fatih; Tunçman, Duygu; Demir, Özge; Uslu-Besli, Lebriz; Günay, Osman; Demir, Mustafa.
Afiliación
  • Yeyin N; Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Fatih/Istanbul, Turkey.
  • Kesmezacar FF; Vocational School of Health Service, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Tunçman D; Vocational School of Health Service, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Demir Ö; Department of Chemical Engineering, Engineering Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Uslu-Besli L; Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Fatih/Istanbul, Turkey.
  • Günay O; Department of Biomedical Engineering, Faculty of Electrical and Electronics Engineering, Yildiz Technical University, Istanbul, Turkey.
  • Demir M; Department of Nuclear Medicine, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Fatih/Istanbul, Turkey.
Curr Radiopharm ; 17(3): 276-284, 2024.
Article en En | MEDLINE | ID: mdl-38288829
ABSTRACT

INTRODUCTION:

The most important toxicity of transarterial radioembolization therapy applied in liver malignancies is radiation pneumonitis and fibrosis due to hepatopulmonary shunt of Yttrium-90 (90Y) microspheres. Currently, Technetium-99m macroaggregated albumin (99mTc-MAA) scintigraphic images are used to estimate lung shunt fraction (LSF) before treatment. The aim of this study was to create a phantom to calculate exact LFS rates according to 99mTc activities in the phantom and to compare these rates with LSF values calculated from scintigraphic images. MATERIALS AND

METHODS:

A 3D-printed lung and liver phantom containing two liver tumors was developed from Polylactic Acid (PLA) material, which is similar to the normal-sized human body in terms of texture and density. Actual %LSFs were calculated by filling phantoms and tumors with 99mTc radionuclide. After the phantoms were placed in the water tank made of plexiglass material, planar, SPECT, and SPECT/CT images were obtained. The actual LSF ratio calculated from the activity amounts filled into the phantom was used for the verification of the quantification of scintigraphic images and the results obtained by the Simplicity90YTM method.

RESULTS:

In our experimental model, LSFs calculated from 99mTc activities filled into the lungs, normal liver, small tumor, and large tumor were found to be 0%, 6.2%, 10.8%, and 16.9%. According to these actual LSF values, LSF values were calculated from planar, SPECT/CT (without attenuation correction), and SPECT/CT (with both attenuation and scatter correction) scintigraphic images of the phantom. In each scintigraphy, doses were calculated for lung, small tumor, large tumor, normal liver, and Simplicity90YTM. The doses calculated from planar and SPECT/CT (NoAC+NoSC) images were found to be higher than the actual doses. The doses calculated from SPECT/CT (with AC+with SC) images and Simplicity90YTM were found to be closer to the real dose values.

CONCLUSION:

LSF is critical in dosimetry calculations of 90Y microsphere therapy. The newly introduced hepatopulmonary shunt phantom in this study is suitable for LSF verification for all models/brands of SPECT and SPECT/CT devices.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radioisótopos de Itrio / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Fantasmas de Imagen / Radiofármacos / Embolización Terapéutica / Neoplasias Hepáticas Límite: Humans Idioma: En Revista: Curr Radiopharm Año: 2024 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radioisótopos de Itrio / Agregado de Albúmina Marcado con Tecnecio Tc 99m / Fantasmas de Imagen / Radiofármacos / Embolización Terapéutica / Neoplasias Hepáticas Límite: Humans Idioma: En Revista: Curr Radiopharm Año: 2024 Tipo del documento: Article País de afiliación: Turquía