Your browser doesn't support javascript.
loading
Lanthanide Complex for Single-Molecule Fluorescent in Situ Hybridization and Background-Free Imaging.
Su, Fei; Chen, Shiyu; Liu, Yuanhua; Zhou, Jiajia; Du, Zhongbo; Luo, Xiongjian; Wen, Shihui; Jin, Dayong.
Afiliación
  • Su F; Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sidney, NSW 2007, Australia.
  • Chen S; UTS-SUStech Joint Research Centre for Biomedical Materials and Devices, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, P. R. China.
  • Liu Y; UTS-SUStech Joint Research Centre for Biomedical Materials and Devices, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, P. R. China.
  • Zhou J; Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sidney, NSW 2007, Australia.
  • Du Z; UTS-SUStech Joint Research Centre for Biomedical Materials and Devices, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, P. R. China.
  • Luo X; UTS-SUStech Joint Research Centre for Biomedical Materials and Devices, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, P. R. China.
  • Wen S; Institute for Biomedical Materials and Devices (IBMD), Faculty of Science, University of Technology Sydney, Sidney, NSW 2007, Australia.
  • Jin D; Eastern Institute for Advanced Study, Eastern Institute of Technology, Ningbo, Zhejiang 315200, P. R. China.
Anal Chem ; 96(11): 4430-4436, 2024 03 19.
Article en En | MEDLINE | ID: mdl-38447029
ABSTRACT
Traditional single-molecule fluorescence in situ hybridization (smFISH) methods for RNA detection often face sensitivity challenges due to the low fluorescence intensity of the probe. Also, short-lived autofluorescence complicates obtaining clear signals from tissue sections. In response, we have developed an smFISH probe using highly grafted lanthanide complexes to address both concentration quenching and autofluorescence background. Our approach involves an oligo PCR incorporating azide-dUTP, enabling conjugation with lanthanide complexes. This method has proven to be stable, convenient, and cost-effective. Notably, for the mRNA detection in SKBR3 cells, the lanthanide probe group exhibited 2.5 times higher luminescence intensity and detected 3 times more signal points in cells compared with the Cy3 group. Furthermore, we successfully applied the probe to image HER2 mRNA molecules in breast cancer FFPE tissue sections, achieving a 2.7-fold improvement in sensitivity compared to Cy3-based probes. These results emphasize the potential of time-resolved smFISH as a highly sensitive method for nucleic acid detection, free of background fluorescence interference.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Elementos de la Serie de los Lantanoides Idioma: En Revista: Anal Chem Año: 2024 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Elementos de la Serie de los Lantanoides Idioma: En Revista: Anal Chem Año: 2024 Tipo del documento: Article País de afiliación: Australia