Your browser doesn't support javascript.
loading
Inter-night variability of in-home, overnight pulse oximetry screening in an asymptomatic older adult population.
Chaudhary, Attiqa; Abbott, Carla J; Wu, Zhichao; Fang, Wendy Y; Raj, Palaniraj R; Naughton, Matthew T; Guymer, Robyn H.
Afiliación
  • Chaudhary A; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia. achaudhary@cera.org.au.
  • Abbott CJ; Department of Surgery (Ophthalmology), The University of Melbourne, Parkville, Australia. achaudhary@cera.org.au.
  • Wu Z; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
  • Fang WY; Department of Surgery (Ophthalmology), The University of Melbourne, Parkville, Australia.
  • Raj PR; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
  • Naughton MT; Department of Surgery (Ophthalmology), The University of Melbourne, Parkville, Australia.
  • Guymer RH; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
Sleep Breath ; 28(3): 1373-1379, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38504043
ABSTRACT

PURPOSE:

Obstructive sleep apnoea (OSA) is common, yet often undiagnosed. Self-administered, overnight pulse oximetry (OPO) could screen for OSA in asymptomatic, older populations. However, the inter-night variability of OPO in an asymptomatic, older population is unknown. We determined the inter-night variability of home OPO parameters in an older population and correlated with sleep questionnaires.

METHODS:

Participants > 50 years without a diagnosis of OSA undertook home OPO for three consecutive nights and completed two sleep questionnaires (STOP-BANG (SBQ) and Epworth Sleepiness Score (ESS)). Analysis was performed with linear mixed models and Spearman's correlation coefficient.

RESULTS:

There was no difference in oxygen desaturation index (ODI), MeanSpO2, MinimumSpO2, and time spent with SpO2 < 90% (T90) across two or three nights (P ≥ 0.282). However, the variability of all parameters across nights increased with the magnitude of departure from normal values (P ≤ 0.002). All OPO parameters were associated with age (P ≤ 0.034) and body mass index (P ≤ 0.049). There was a weak correlation between three OPO parameters and SBQ (absolute ρ = 0.22 to 0.32; P ≤ 0.021), but not ESS (P ≥ 0.254).

CONCLUSION:

Inter-night variability of home OPO was minimal when values were near-normal in an older population. However, as values depart from normal, the inter-night variability increases, indicating the need for multiple night recordings. Low correlation to sleep questionnaires suggest the need for more robust OSA questionnaires in an asymptomatic population.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Oximetría / Tamizaje Masivo / Apnea Obstructiva del Sueño Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sleep Breath Asunto de la revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Oximetría / Tamizaje Masivo / Apnea Obstructiva del Sueño Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sleep Breath Asunto de la revista: NEUROLOGIA / OTORRINOLARINGOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Australia