Your browser doesn't support javascript.
loading
Quality assurance of late gadolinium enhancement cardiac magnetic resonance images: a deep learning classifier for confidence in the presence or absence of abnormality with potential to prompt real-time image optimization.
Zaman, Sameer; Vimalesvaran, Kavitha; Chappell, Digby; Varela, Marta; Peters, Nicholas S; Shiwani, Hunain; Knott, Kristopher D; Davies, Rhodri H; Moon, James C; Bharath, Anil A; Linton, Nick Wf; Francis, Darrel P; Cole, Graham D; Howard, James P.
Afiliación
  • Zaman S; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; Imperial College Healthcare NHS Trust, London W12 0HS, UK; AI for Healthcare Centre for Doctoral Training, Imperial College London, London SW7 2AZ, UK.
  • Vimalesvaran K; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; AI for Healthcare Centre for Doctoral Training, Imperial College London, London SW7 2AZ, UK.
  • Chappell D; AI for Healthcare Centre for Doctoral Training, Imperial College London, London SW7 2AZ, UK.
  • Varela M; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK.
  • Peters NS; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; Imperial College Healthcare NHS Trust, London W12 0HS, UK.
  • Shiwani H; Institute of Cardiovascular Science, University College London, London WC1E 6DD, UK; Barts Health Centre, St. Bartholomew's Hospital, London EC1A 7BE, UK.
  • Knott KD; Institute of Cardiovascular Science, University College London, London WC1E 6DD, UK; St. George's University Hospitals NHS Foundation Trust, London SW17 0QT, UK.
  • Davies RH; Institute of Cardiovascular Science, University College London, London WC1E 6DD, UK; Barts Health Centre, St. Bartholomew's Hospital, London EC1A 7BE, UK.
  • Moon JC; Institute of Cardiovascular Science, University College London, London WC1E 6DD, UK; Barts Health Centre, St. Bartholomew's Hospital, London EC1A 7BE, UK.
  • Bharath AA; Department of Bioengineering, Imperial College London, London SW7 2AZ, UK.
  • Linton NW; Imperial College Healthcare NHS Trust, London W12 0HS, UK; Department of Bioengineering, Imperial College London, London SW7 2AZ, UK. Electronic address: n.linton@imperial.ac.uk.
  • Francis DP; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; Imperial College Healthcare NHS Trust, London W12 0HS, UK.
  • Cole GD; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; Imperial College Healthcare NHS Trust, London W12 0HS, UK.
  • Howard JP; National Heart and Lung Institute, Imperial College London, London SW7 2AZ, UK; Imperial College Healthcare NHS Trust, London W12 0HS, UK.
J Cardiovasc Magn Reson ; 26(1): 101040, 2024.
Article en En | MEDLINE | ID: mdl-38522522
ABSTRACT

BACKGROUND:

Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports.

METHODS:

Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (701515). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center.

RESULTS:

One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86.

CONCLUSION:

Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Valor Predictivo de las Pruebas / Medios de Contraste / Aprendizaje Profundo Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Valor Predictivo de las Pruebas / Medios de Contraste / Aprendizaje Profundo Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido