Your browser doesn't support javascript.
loading
Quantification and Influence of IL-1ß on Pain and Inflammatory Response after Placement of a Cement-Screw-Retained Restoration.
Arbelaez-Bonozo, Lady; Maza-Solano, Serafín; Baus-Domínguez, María; Gómez-Díaz, Raquel; Ruiz-de-Leon-Pacheco, Gonzalo; Torres-Lagares, Daniel; Serrera-Figallo, María-Angeles.
Afiliación
  • Arbelaez-Bonozo L; Department of Stomatology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
  • Maza-Solano S; Department of Stomatology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
  • Baus-Domínguez M; Department of Stomatology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
  • Gómez-Díaz R; Institute of Biomedicine of Seville, 41013 Seville, Spain.
  • Ruiz-de-Leon-Pacheco G; Gregorio Marañón General University Hospital, 28007 Madrid, Spain.
  • Torres-Lagares D; Department of Stomatology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
  • Serrera-Figallo MA; Department of Stomatology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
J Clin Med ; 13(6)2024 Mar 14.
Article en En | MEDLINE | ID: mdl-38541894
ABSTRACT

Background:

The objective of this study was to evaluate the pain and inflammatory response in soft tissues using healing and prosthetic abutments of different diameters and lengths.

Methods:

The study population was rehabilitated with Astra Tech EV single implants (Dentsply Sirona, Atlantis, Dentsply Sirona S.A., Barcelona, Spain) of 4.2 and 4.8 millimetres in diameter in the upper and lower maxilla and loaded with custom abutments digitally designed using Dentsply Sirona's Virtual Atlantis Design software (Atlantis WebOrder, Dentsply Sirona S.A., Barcelona, Spain), version 4.6.5. The custom abutments had a larger diameter than the healing abutments to evaluate for biomarkers through ELISA.

Results:

Rehabilitations in the mandible and with healing abutments with diameters less than 4.29 mm and rehabilitators with diameters less than 2.18 mm elicited a higher pain and inflammatory response and, in turn, higher interleukin-1ß values.

Conclusions:

Greater inflammation was evident in cases in which healing abutments with reduced diameter were used compared to the same subsequent rehabilitation with prosthetic abutments with larger diameters.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2024 Tipo del documento: Article País de afiliación: España

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Clin Med Año: 2024 Tipo del documento: Article País de afiliación: España