Your browser doesn't support javascript.
loading
Effects of low-flux and high-flux hemodialysis on the survival of elderly maintenance hemodialysis patients.
Huang, Wanqing; Bai, Jiuxu; Zhang, Yanping; Qiu, Dongxia; Wei, Lin; Zhao, Chen; Ren, Zhuo; Wang, Qian; Ren, Kaiming; Cao, Ning.
Afiliación
  • Huang W; Postgraduate., Training Base of Jinzhou Medical University (General Hospital of Northern Theater Command), Jinzhou, China.
  • Bai J; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Zhang Y; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Qiu D; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Wei L; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Zhao C; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Ren Z; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Wang Q; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Ren K; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
  • Cao N; Department of Blood Purification, General Hospital of Northern Theater Command, Shenyang, China.
Ren Fail ; 46(1): 2338217, 2024 Dec.
Article en En | MEDLINE | ID: mdl-38584147
ABSTRACT

BACKGROUND:

Elderly hemodialysis (HD) patients have a high risk of death. The effect of different types of HD membranes on survival is still controversial. The purpose of this study was to determine the relationship between the use of low-flux or high-flux membranes and all-cause and cardiovascular mortality in elderly hemodialysis patients.

METHODS:

This was a retrospective clinical study involving maintenance hemodialysis patients which were categorized into low-flux and high-flux groups according to the dialyzer they were using. Propensity score matching was used to balance the baseline data of the two groups. Survival rates were compared between the two groups, and the risk factors for death were analyzed by multivariate Cox regression.

RESULTS:

Kaplan-Meier survival analysis revealed no significant difference in all-cause mortality between the low-flux group and the high-flux group (log-rank test, p = 0.559). Cardiovascular mortality was significantly greater in the low-flux group than in the high-flux group (log-rank test, p = 0.049). After adjustment through three different multivariate models, we detected no significant difference in all-cause mortality. Patients in the high-flux group had a lower risk of cardiovascular death than did those in the low-flux group (HR = 0.79, 95% CI, 0.54-1.16, p = 0.222; HR = 0.58, 95% CI, 0.37-0.91, p = 0.019).

CONCLUSIONS:

High-flux hemodialysis was associated with a lower relative risk of cardiovascular mortality in elderly MHD patients. High-flux hemodialysis did not improve all-cause mortality rate. Differences in urea distribution volume, blood flow, and systemic differences in solute clearance by dialyzers were not further analyzed, which are the limitations of this study.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedades Cardiovasculares / Fallo Renal Crónico Límite: Aged / Humans Idioma: En Revista: Ren Fail Asunto de la revista: NEFROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedades Cardiovasculares / Fallo Renal Crónico Límite: Aged / Humans Idioma: En Revista: Ren Fail Asunto de la revista: NEFROLOGIA Año: 2024 Tipo del documento: Article País de afiliación: China