Your browser doesn't support javascript.
loading
Fabrication and application of a continuously regenerated cationic impurity removal device for ion chromatography.
Li, Yihua; Zhang, Tianyang; Zhang, Feifang; Chen, Weiqing; Yang, Bingcheng.
Afiliación
  • Li Y; Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China.
  • Zhang T; Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China.
  • Zhang F; Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China. Electronic address: zhangff@ecust.edu.cn.
  • Chen W; Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China.
  • Yang B; Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China. Electronic address: bcyang@ecust.edu.cn.
J Chromatogr A ; 1722: 464904, 2024 May 10.
Article en En | MEDLINE | ID: mdl-38626539
ABSTRACT
A continuously regenerated cationic impurity removal device (CR-CRD) has been fabricated and applied for ion chromatography (IC). The removal of cationic impurities is realized by electrodialytically replacing the cationic impurities with hydronium ions. The device is configured in a sandwich structure and the central eluent channel is respectively isolated from both electrodes by stacked cation exchange membranes and a bipolar membrane (BPM) plus stacked anion exchange membranes. The eluent channel is packed with cation exchange resins in hydronium form and their continuous regeneration can be achieved by electrodialysis. A desirable feature of the device is gas-free, and no degasser is required. It showed sufficient ability to remove cationic impurities, as indicated by > 99.9 % removal of 10 mL of 1 mM LiOH solution injected (∼10 µmol) or continuous removal of 1 mM LiOH solution at the flow rate of 1 mL/min (1 µmol/min). A useful application was for sample pretreatment in nuclear power industry, by eliminating strong matrix interference of the sample containing LiOH (1 mM) and boric acid (2000 mg/L) with trace anion analysis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cationes Idioma: En Revista: J Chromatogr A Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Cationes Idioma: En Revista: J Chromatogr A Año: 2024 Tipo del documento: Article País de afiliación: China