Your browser doesn't support javascript.
loading
Hard X-ray imaging and tomography at the Biomedical Imaging and Therapy beamlines of Canadian Light Source.
Gasilov, Sergey; Webb, M Adam; Panahifar, Arash; Zhu, Ning; Marinos, Omar; Bond, Toby; Cooper, David M L; Chapman, Dean.
Afiliación
  • Gasilov S; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Webb MA; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Panahifar A; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Zhu N; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Marinos O; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Bond T; Canadian Light Source, 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada.
  • Cooper DML; College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon S7N 5E5, Canada.
  • Chapman D; College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon S7N 5E5, Canada.
J Synchrotron Radiat ; 31(Pt 5): 1346-1357, 2024 Sep 01.
Article en En | MEDLINE | ID: mdl-39007824
ABSTRACT
The Biomedical Imaging and Therapy facility of the Canadian Light Source comprises two beamlines, which together cover a wide X-ray energy range from 13 keV up to 140 keV. The beamlines were designed with a focus on synchrotron applications in preclinical imaging and veterinary science as well as microbeam radiation therapy. While these remain a major part of the activities of both beamlines, a number of recent upgrades have enhanced the versatility and performance of the beamlines, particularly for high-resolution microtomography experiments. As a result, the user community has been quickly expanding to include researchers in advanced materials, batteries, fuel cells, agriculture, and environmental studies. This article summarizes the beam properties, describes the endstations together with the detector pool, and presents several application cases of the various X-ray imaging techniques available to users.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sincrotrones Límite: Animals / Humans País/Región como asunto: America do norte Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Sincrotrones Límite: Animals / Humans País/Región como asunto: America do norte Idioma: En Revista: J Synchrotron Radiat Asunto de la revista: RADIOLOGIA Año: 2024 Tipo del documento: Article País de afiliación: Canadá