Your browser doesn't support javascript.
loading
Comparison of stereoscopic digital imaging and slide film photography in the identification of macular degeneration.
Somani, Riz; Tennant, Matt; Rudnisky, Chris; Weis, Ezekiel; Ting, Andrew; Eppler, Jayson; Greve, Mark; Hinz, Brad; de Leon, Alex.
Afiliação
  • Somani R; Department of Ophthalmology, Royal Alexandra Hospital, University of Alberta, Edmonton, Canada.
Can J Ophthalmol ; 40(3): 293-302, 2005 Jun.
Article em En | MEDLINE | ID: mdl-15947799
ABSTRACT

BACKGROUND:

This study compared the sensitivity and specificity of stereoscopic digital photography of the retina through a dilated pupil with a 45 degrees nonmydriatic camera and Joint Photographic Experts Group (JPEG) compression of the images with the sensitivity and specificity of 35-mm slide film photography in the identification of age-related macular degeneration (AMD).

METHODS:

Consecutive patients with a diagnosis of AMD were enrolled. Stereoscopic retinal images of the disc, macula and temporal macula were captured with a digital 45 degrees nonmydriatic camera (then compressed into JPEG format) and with a standard fundus camera and slide film. A single retinal specialist graded both image formats in masked fashion, at least 1 month apart, using a modified Age-Related Eye Disease Study (AREDS) severity scale. The digital images were displayed on a monitor and viewed with the use of liquid crystal display shutter glasses and stereo imaging software. The film images were mounted on a light box and graded with the use of a stereoviewer. Primary outcome measures included the presence or absence of AMD pathological features. Positive and negative predictive values (PPVs and NPVs), sensitivity, specificity and weighted kappaw statistics were calculated.

RESULTS:

We photographed 203 eyes (of 103 patients) with both digital and slide film cameras. Correlation of the 2 image formats was substantial in identifying AREDS level 3a or greater (kappaw=0.64, standard error=0.08, PPV=0.95, NPV=0.66, sensitivity=0.93, specificity=0.74) and excellent in identifying level 4b or greater (kappaw=0.83, standard error=0.05, PPV=0.81, NPV=0.98, sensitivity=0.94, specificity=0.94).

INTERPRETATION:

High-resolution stereoscopic, mydriatic, 45 degrees digital images captured with a nonmydriatic camera and JPEG compressed correlate well with stereoscopic slide film photographs in the identification of moderate to advanced AMD (AREDS level 3a or greater).
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retina / Aumento da Imagem / Fotografação / Degeneração Macular Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Can J Ophthalmol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Canadá
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retina / Aumento da Imagem / Fotografação / Degeneração Macular Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Can J Ophthalmol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Canadá