Your browser doesn't support javascript.
loading
Determination of patch electrode position for the internal cardioverter-defibrillator by cine computed tomography and its relation to the defibrillation threshold.
Oeff, M; Abbott, J A; Scheinman, E D; Yee, E S; Scheinman, M M; Griffin, J C.
Afiliação
  • Oeff M; Department of Medicine, University of California, San Francisco.
J Am Coll Cardiol ; 20(1): 210-7, 1992 Jul.
Article em En | MEDLINE | ID: mdl-1607527
ABSTRACT
Cardioverter-defibrillator implantation in 22 consecutive patients after aborted sudden cardiac death was followed by prospective determination of the correct anatomic position of epicardial patch electrodes by chest X-ray study and cine computed tomography; the data were compared with the defibrillation threshold obtained intraoperatively. Patch electrode position was qualitatively graded. Computed tomography improved the assessment as compared with X-ray study in 13 patients (59%), visualizing electrodes in relation to the underlying myocardial and vascular structures. Although the computed tomographic technique provided more precise visualization, its grading of patch position correlated as poorly as that of the X-ray study with the measured acute defibrillation threshold. Three-dimensional reconstruction by computed tomography made it possible to determine quantitatively left ventricular mass (free wall and septum) and the mass encompassed by the patch electrodes. The 34.6 +/- 13.7% (range 12.6 to 61.1%) of the left ventricular mass encompassed by both patch electrodes showed a linear relation to the defibrillation threshold (r = 0.64, p = 0.01). Differentiation of free wall and septal mass in these measurements revealed that the proportion of septal mass encompassed by patch electrodes correlated closely with the defibrillation threshold (r = -0.6, p = 0.019), whereas that of the free wall mass, although significantly larger (35.4 +/- 15.8 vs. 20.6 +/- 15.4 g, p = 0.007), did not. Thus, the position of epicardial patch electrodes could be reliably determined by computed tomography.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardioversão Elétrica / Estimulação Cardíaca Artificial / Radiografia Torácica / Tomografia Computadorizada por Raios X / Eletrodos Implantados Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1992 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardioversão Elétrica / Estimulação Cardíaca Artificial / Radiografia Torácica / Tomografia Computadorizada por Raios X / Eletrodos Implantados Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Am Coll Cardiol Ano de publicação: 1992 Tipo de documento: Article