Your browser doesn't support javascript.
loading
Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.
Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A.
Afiliação
  • Turan S; Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland, Baltimore, MD 21201, USA.
Ultrasound Obstet Gynecol ; 33(6): 652-6, 2009 Jun.
Article em En | MEDLINE | ID: mdl-19405042
ABSTRACT

OBJECTIVE:

The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy.

METHODS:

Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler.

RESULTS:

107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%).

CONCLUSION:

Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Cardíaco / Ultrassonografia Pré-Natal / Ecocardiografia Doppler em Cores / Coração Fetal Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Volume Cardíaco / Ultrassonografia Pré-Natal / Ecocardiografia Doppler em Cores / Coração Fetal Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Assunto da revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Estados Unidos