Bench-scale tests on ultrasound-assisted acid washing and thermal desorption of mercury from dredging sludge and other solid matrices.
Lesa, Barbara; Aneggi, Eleonora; Rossi, Giada; Comuzzi, Clara; Goi, Daniele.
Afiliação
  • Lesa B; Dipartimento di Scienze e Tecnologie Chimiche, Università degli Studi di Udine, via del Cotonificio, 108 - 33100 Udine, Italy.
J Hazard Mater ; 171(1-3): 647-53, 2009 Nov 15.
Article em En | MEDLINE | ID: mdl-19586719
ABSTRACT
A series of ultrasonic assisted acid washing and thermal desorption tests were performed on sludge and other solid matrices with the aim to assay these removal technologies and to determine if the application of low frequency ultrasound was effective to enhance mercury removal. Unpolluted dredging sludge, 820 K calcinated dredging sludge, silica and alumina were characterized, polluted with a known concentration of mercury and treated both by acid washing and thermal desorption with and without low frequency ultrasound application. The acid washing was carried out by a 4% HNO(3) acid solution and the thermal desorption was performed in a 370-620K range. X-ray semi-quantitative analysis of dredging sludge before and after acid washing and granulometric curves of the matrices after the ultrasonic treatment were considered in order to evidence chemical or physical changes during these treatments. Total residual mercury measurements were carried out before and after sonication. Results showed not measurable acid washing extraction from polluted dredging sludge, a little (3%) extraction from 820K heat-treated sludge and a significant (10-20%) extraction from alumina and silica within 120 min of treatment. The ultrasound application gave generally poor improvement of the mercury removal. On the contrary thermal desorption of mercury was somewhat effective for alumina, silica and heat-treated dredging sludge samples in which mercury removal was 30-40% at 370 K and 90-99% at 570 K. Likewise ultrasound application did not improve desorption. Instead, the thermal treatment of dredging sludge had a negligible amount of mercury desorption at 370 K but it reached 95% at 570 K. The application of ultrasound improved the thermal extraction of 25% in the 470-520 K range of temperature.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esgotos / Ultrassom / Eliminação de Resíduos Líquidos / Purificação da Água / Mercúrio Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esgotos / Ultrassom / Eliminação de Resíduos Líquidos / Purificação da Água / Mercúrio Idioma: En Revista: J Hazard Mater Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Itália