Your browser doesn't support javascript.
loading
Volume-targeted and whole-heart coronary magnetic resonance angiography using an intravascular contrast agent.
Tang, Lijun; Merkle, Nico; Schär, Michael; Korosoglou, Grigorios; Solaiyappan, Meiyappan; Hombach, Vinzenz; Stuber, Matthias.
Afiliação
  • Tang L; Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
J Magn Reson Imaging ; 30(5): 1191-6, 2009 Nov.
Article em En | MEDLINE | ID: mdl-19856454
ABSTRACT

PURPOSE:

To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND

METHODS:

Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA.

RESULTS:

No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA 6.05 min; 49% vs. WH-CMRA 5.51 min; 54%, both P = NS).

CONCLUSION:

Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Meios de Contraste / Vasos Coronários / Coração Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2009 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Meios de Contraste / Vasos Coronários / Coração Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2009 Tipo de documento: Article País de afiliação: China