Your browser doesn't support javascript.
loading
Agreement between paper and pen visual analogue scales and a wristwatch-based electronic appetite rating system (PRO-Diary©), for continuous monitoring of free-living subjective appetite sensations in 7-10 year old children.
Rumbold, P L S; Dodd-Reynolds, C J; Stevenson, E.
Afiliação
  • Rumbold PL; Faculty of Health and Life Sciences, Department of Sport, Exercise and Rehabilitation, Northumbria University, Northumberland Building, Newcastle upon Tyne NE1 8ST, UK. penny.rumbold@northumbria.ac.uk
Appetite ; 69: 180-5, 2013 Oct.
Article em En | MEDLINE | ID: mdl-23770207
ABSTRACT
Electronic capture of free-living subjective appetite data can provide a more reliable alternative to traditional pen and paper visual analogue scales (P&P VAS), whilst reducing researcher workload. Consequently, the aim of this study was to explore the agreement between P&P VAS and a wristwatch-based electronic appetite rating system known as the PRO-Diary© technique, for monitoring free-living appetite sensations in 7-10 year old children. On one occasion, using a within-subject design, the 12 children (n=6 boys; n=6 girls) recorded their subjective appetite (hunger, prospective food consumption, and fullness), at two time points before lunch (1130 and 1200) and every 60 min thereafter until 2100. The agreement between the P&P VAS and PRO-Diary© technique was explored using 95% limits of agreement and 95% confidence intervals (95% CI) calculated using the Bland and Altman (1986) technique. For hunger, prospective food consumption and fullness, the 95% limits of agreement were -1±25 mm (95% CI lower limit -8mm; upper limit +6mm), 0±21 mm (95% CI lower limit -6mm; upper limit +6mm) and -6±24 mm (95% CI lower limit -14 mm; upper limit +1mm), respectively. Given the advantages associated with electronic data capture (inexpensive; integrated alarm; data easily downloaded), we conclude that the PRO-Diary© technique is an equivalent method to employ when continuously monitoring free-living appetite sensations in 7-10 year old children, but should not be used interchangeably with P&P VAS.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apetite / Monitorização Fisiológica Limite: Child / Female / Humans / Male Idioma: En Revista: Appetite Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apetite / Monitorização Fisiológica Limite: Child / Female / Humans / Male Idioma: En Revista: Appetite Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Reino Unido