Your browser doesn't support javascript.
loading
Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study.
Eur Heart J ; 35(17): 1120-30, 2014 May.
Article em En | MEDLINE | ID: mdl-24255127
ABSTRACT

AIMS:

To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT). METHODS AND

RESULTS:

We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI) 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels.

CONCLUSIONS:

The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Estenose Coronária Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Heart J Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Estenose Coronária Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Heart J Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos