ABSTRACT

BACKGROUND:

Postoperative atrial fibrillation (POAF) is a common complication of cardiac surgery and may result in stroke or heart failure and poor prognosis. This study aimed to evaluate a novel index of total atrial conduction time derived from the P-wave onset (lead II) to the peak A' wave on tissue Doppler imaging (PA-TDI duration). The PA-TDI duration was compared with previously reported predictors of POAF, and the optimal cutoff value of PA-DTI was calculated in patients undergoing aortic valve replacement (AVR) for AV stenosis (AS). METHODS AND 

RESULTS:

We enrolled 63 patients undergoing isolated AVR. They underwent transthoracic echocardiography with TDI preoperatively and were monitored postoperatively with continuous electrocardiographic telemetry for 7 days. The hospital stay was significantly longer in the 41 patients with POAF than in the 22 without POAF (33.8±19.7 vs. 24.1±8.1 days, P=0.03). Multivariate analysis revealed that PA-TDI duration (odds ratio [OR], 1.07; 95% confidence interval [CI], 1.02-1.13; P=0.0072) and age (OR, 1.14; CI, 1.03-1.28; P=0.016) were significant independent predictors of POAF. Receiver-operating characteristic curve analysis showed the optimal cutoff values of PA-TDI duration and age were 147.3 ms and 74 years, respectively.

CONCLUSIONS:

The PA-TDI duration was an independent predictor of POAF after AVR for AS. Patients with PA-TDI duration >147 ms should be considered high risk and treated appropriately to improve outcomes.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Complicações Pós-Operatórias / Fibrilação Atrial / Ecocardiografia Doppler / Implante de Prótese de Valva Cardíaca / Sistema de Condução Cardíaco Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Complicações Pós-Operatórias / Fibrilação Atrial / Ecocardiografia Doppler / Implante de Prótese de Valva Cardíaca / Sistema de Condução Cardíaco Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Circ J Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article