Your browser doesn't support javascript.
loading
Assessment of anterior chamber parameters after cataract surgery by Galilei dual Scheimpflug analyzer.
Yagci, Ramazan; Güler, Emre; Uzun, Feyza; Güragaç, Betül F; Acer, Semra; Hepsen, Ibrahim F.
Afiliação
  • Yagci R; Department of Ophthalmology (R.Y., S.A.), Pamukkale University Medical School, Denizli, Turkey; Department of Ophthalmology (E.G.), Ercis State Hospital, Van, Turkey; Department of Ophthalmology (B.F.G.), Turgut Ozal University Medical School, Ankara, Turkey; Department of Ophthalmology (F.U.), Trabzon Arakli Bayram Halil Devlet Hastanesi, Trabzon, Turkey; and Department of Ophthalmology (I.F.H.), Gazi University Medical School, Ankara, Turkey.
Eye Contact Lens ; 41(1): 40-3, 2015 Jan.
Article em En | MEDLINE | ID: mdl-25083777
ABSTRACT

OBJECTIVE:

To quantify the difference between anterior chamber parameters determined by the Galilei dual Scheimpflug analyzer after uneventful cataract surgery in normotensive eyes.

METHODS:

In this study, 39 eyes of 30 patients (11 men and 19 women) who had uneventful cataract surgery with phacoemulsification were evaluated preoperatively, and at 1 month postoperatively with the Galilei. We investigated the measurements including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and the 3-, 5-, and 7-mm corneal thickness (CT) preoperatively and postoperatively.

RESULTS:

The differences between ACD (P=0.01), ACA (P=0.07), ACV (P=0.01), and 7-mm CT (P=0.01), and intraocular pressure (P=0.03) were statistically significant after the first month of phacoemulsification. However, the differences between CCT (P=0.60), 3-mm CT (P=0.75), and 5-mm (P=0.17) CT were not statistically significant.

CONCLUSIONS:

After the first month of cataract surgery, a significant increase was observed in ACD, ACV, ACA, and 7-mm CT parameters, which were practically determined by a new noncontact Scheimpflug imagining system.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Fotografação / Facoemulsificação / Topografia da Córnea / Câmara Anterior Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eye Contact Lens Assunto da revista: OFTALMOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Fotografação / Facoemulsificação / Topografia da Córnea / Câmara Anterior Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eye Contact Lens Assunto da revista: OFTALMOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia