Your browser doesn't support javascript.
loading
Generation of an anti-Dabigatran Monoclonal Antibody and Its Use in a Highly Sensitive and Specific Enzyme-Linked Immunosorbent Assay for Serum Dabigatran.
Oiso, Shigeru; Morinaga, Osamu; Goroku, Takaaki; Uto, Takuhiro; Shoyama, Yukihiro; Kariyazono, Hiroko.
Afiliação
  • Oiso S; *Graduate School of Pharmaceutical Sciences; Departments of †Pharmaceutical Health Care Sciences; and ‡Pharmacognosy, Faculty of Pharmaceutical Sciences, Nagasaki International University, Japan.
Ther Drug Monit ; 37(5): 594-9, 2015 Oct.
Article em En | MEDLINE | ID: mdl-25565675
ABSTRACT

BACKGROUND:

Dabigatran (DT) is a direct thrombin inhibitor used to prevent venous and arterial thromboembolism due to atrial fibrillation. DT is the active form of the commercially available prodrug DT etexilate. Although DT has many clinical advantages over warfarin, it increases the incidence of bleeding in patients with renal dysfunction. Circulating levels of DT are increased in such patients because it is mainly eliminated by renal excretion. Therapeutic drug monitoring may therefore help to prevent adverse DT effects, but no method for measuring circulating DT levels has been reported, except for an analysis by liquid chromatography-tandem mass spectrometry. This study sought to develop a novel enzyme-linked immunosorbent assay (ELISA) to measure DT concentrations.

METHODS:

Mice were immunized with a DT-keyhole limpet hemocyanin conjugate to generate an anti-DT antibody. Immunized mouse splenocytes and myeloma cells (SP2/0) were fused to obtain an anti-DT monoclonal antibody (DT-mAb). DT-mAb and DT solutions were added to microplate wells coated with a DT-human serum albumin conjugate. DT concentrations were determined based on the principles of ELISA.

RESULTS:

DT-mAb was successfully purified from a hybridoma, and the competitive ELISA developed using this DT-mAb could evaluate DT concentrations ranging from 7.8 to 125 ng/mL. The ELISA signal was not linear using DT-spiked serum; however, it was linear when serum ultrafiltrate was used. Weak cross-reactivity with DT etexilate was detected, but no cross-reactivity was observed with other structurally related drugs or drugs commonly used for the treatment of atrial fibrillation.

CONCLUSIONS:

The developed competitive ELISA is a valuable and specific tool to analyze free DT in serum ultrafiltrate for therapeutic drug monitoring and pharmacokinetic studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Dabigatrana / Anticorpos Monoclonais Tipo de estudo: Diagnostic_studies Limite: Animals / Humans / Male Idioma: En Revista: Ther Drug Monit Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Dabigatrana / Anticorpos Monoclonais Tipo de estudo: Diagnostic_studies Limite: Animals / Humans / Male Idioma: En Revista: Ther Drug Monit Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão