Your browser doesn't support javascript.
loading
Selective separation and determination of the synthetic colorants in beverages by magnetic solid-phase dispersion extraction based on a Fe3 O4 /reduced graphene oxide nanocomposite followed by high-performance liquid chromatography with diode array detection.
Wang, Xi; Chen, Ning; Han, Qing; Yang, Zaiyue; Wu, Jinhua; Xue, Cheng; Hong, Junli; Zhou, Xuemin; Jiang, Huijun.
Afiliação
  • Wang X; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Chen N; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Han Q; Jiangsu Provincial Institute of Materia Medica, Nanjing Tech University, Nanjing, P. R. China.
  • Yang Z; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Wu J; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Xue C; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Hong J; Institute of Medicine and Chemical Industry, China Pharmaceutical University, Nanjing, P. R. China.
  • Zhou X; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
  • Jiang H; School of Pharmacy, Nanjing Medical University, Nanjing, P. R. China.
J Sep Sci ; 38(12): 2167-73, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25864558
ABSTRACT
A facile adsorbent, a nanocomposite of Fe3 O4 and reduced graphene oxide, was fabricated for the selective separation and enrichment of synthetic aromatic azo colorants by magnetic solid-phase dispersion extraction. The nanocomposite was synthesized in a one-step reduction reaction and characterized by atomic force microscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, X-ray diffraction and Brunauer-Emmett-Teller analysis. The colorants in beverages were quickly adsorbed onto the surface of the nanocomposite with strong π-π interactions between colorants and reduced graphene oxide, and separated with the assistance of an external magnetic field. Moreover, the four colorants in beverages were detected at different wavelengths by high performance liquid chromatography with diode array detection. A linear dependence of peak area was obtained over 0.05-10 µg/mL with the limits of detection of 10.02, 11.90, 10.41, 15.91 ng/mL for tartrazine, allure red, amaranth, and new coccine, respectively (signal to noise = 3). The recoveries for the spiked colorants were in the range of 88.95-95.89% with the relative standard deviation less than 2.66%. The results indicated that the nanocomposite of Fe3 O4 and reduced graphene oxide could be used as an excellent selective adsorbent for aromatic compounds and has potential applications in sample pretreatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Bebidas / Compostos Férricos / Nanocompostos / Corantes de Alimentos / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Óxidos / Bebidas / Compostos Férricos / Nanocompostos / Corantes de Alimentos / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2015 Tipo de documento: Article