Your browser doesn't support javascript.
loading
Patellar Fractures: An Innovative Surgical Technique With Transosseous Suture to Avoid Implant Removal.
Buezo, Oscar; Cuscó, Xavier; Seijas, Roberto; Sallent, Andrea; Ares, Oscar; Álvarez-Díaz, Pedro; Cugat, Ramón.
Afiliação
  • Buezo O; Mutua Montañesa, MATEPSS 7, Barcelona, Spain.
  • Cuscó X; Fundación García Cugat, Hospital Quirón, Barcelona, Spain.
  • Seijas R; Fundación García Cugat, Hospital Quirón, Barcelona, Spain roberto6jas@gmail.com.
  • Sallent A; Hospital Vall d'Hebron, Barcelona, Spain.
  • Ares O; Fundación García Cugat, Hospital Quirón, Barcelona, Spain.
  • Álvarez-Díaz P; Fundación García Cugat, Hospital Quirón, Barcelona, Spain.
  • Cugat R; Fundación García Cugat, Hospital Quirón, Barcelona, Spain.
Surg Innov ; 22(5): 474-8, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26142416
ABSTRACT

PURPOSE:

To describe a new surgical procedure and its

outcomes:

osteosynthesis with high-resistance sutures, avoiding metallic implants. Open sky osteosynthesis with Kirschner and cerclage wiring is the current gold standard for patella fractures. Favorable functional outcomes have been observed, although implant removal is required in many cases due to the prominent wires under the skin. New implants have been sought after to minimize the need for second surgeries.

METHODS:

Eight patients, aged between 25 and 61 years, with a minimum follow-up of 24 months, were included in the present study. The surgical procedure consists of open reduction followed by internal fixation performing 3 longitudinal tunnels crossing double high-resistance sutures within these tunnels and suturing among them. Next, an anterior cerclage with parenchymal suture was performed.

RESULTS:

During follow-up, no secondary fracture displacement was observed. No patient required or requested implant removal. Functional outcomes were equitable to other surgical techniques.

CONCLUSION:

Despite the relatively small number of patients, osteosynthesis with high-resistance suture presents as an acceptable alternative within patella fracture treatment, being safe and with similar functional outcomes when compared with other techniques. Furthermore, no second surgeries for implant removal were required during the present study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patela / Suturas / Remoção de Dispositivo / Fraturas Ósseas / Fixação Interna de Fraturas Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Surg Innov Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Patela / Suturas / Remoção de Dispositivo / Fraturas Ósseas / Fixação Interna de Fraturas Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Surg Innov Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Espanha