Device landing zone calcification and its impact on residual regurgitation after transcatheter aortic valve implantation with different devices.
Seiffert, Moritz; Fujita, Buntaro; Avanesov, Maxim; Lunau, Clemens; Schön, Gerhard; Conradi, Lenard; Prashovikj, Emir; Scholtz, Smita; Börgermann, Jochen; Scholtz, Werner; Schäfer, Ulrich; Lund, Gunnar; Ensminger, Stephan; Treede, Hendrik.
Afiliação
  • Seiffert M; Department of General and Interventional Cardiology, University Heart Center Hamburg, Martinistrasse 52, Hamburg 20246, Germany m.seiffert@uke.de.
  • Fujita B; Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Avanesov M; Department of Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Lunau C; Department of General and Interventional Cardiology, University Heart Center Hamburg, Martinistrasse 52, Hamburg 20246, Germany.
  • Schön G; Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Conradi L; Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
  • Prashovikj E; Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Scholtz S; Department of Cardiology, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Börgermann J; Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Scholtz W; Department of Cardiology, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Schäfer U; Department of General and Interventional Cardiology, University Heart Center Hamburg, Martinistrasse 52, Hamburg 20246, Germany.
  • Lund G; Department of Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Ensminger S; Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Bad Oeynhausen, Germany.
  • Treede H; Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
Eur Heart J Cardiovasc Imaging ; 17(5): 576-84, 2016 May.
Article em En | MEDLINE | ID: mdl-26160399
ABSTRACT

AIMS:

Calcification of the device landing zone is linked to paravalvular regurgitation after transcatheter aortic valve implantation (TAVI). The mechanisms remain incompletely understood and the performance of next-generation transcatheter heart valves (THV) has not been investigated. We evaluated the impact of calcification patterns on residual aortic regurgitation (AR) after TAVI with different THV in patients with severe aortic stenosis. METHODS AND

RESULTS:

TAVI was performed in 537 patients at two centres. Devices implanted were the Edwards Sapien XT (n = 254), Medtronic CoreValve (n = 123), JenaValve (n = 62), Medtronic Engager (n = 56), and Symetis Acurate (n = 42) prostheses. Calcification of the device landing zone was retrospectively assessed from contrast-enhanced multidetector computed tomography data and correlated with echocardiographic and clinical data. Calcium volumes of the aortic valve and left-ventricular outflow tract were associated with residual AR No AR, 604 mm(3) (inter-quartile range, IQR 349-916); trace AR, 639 mm(3) (IQR 368-948); mild AR, 710 mm(3) (IQR 412-2078); ≥moderate AR, 1041 mm(3) (IQR 791-1417, P = 0.001). Device landing zone calcium, particularly if located in the left-ventricular outflow tract, and a low cover index were predictive of AR. Differences in the incidence of AR were observed with regard to THV type. Higher calcium volume was associated with the need for post-dilation (n = 134, median 852 [IQR 342-945] vs. 604 [IQR 542-1207] mm(3), P < 0.001).

CONCLUSION:

Calcification of the device landing zone, particularly if located inferior to the annulus, was independently associated with residual AR after TAVI with all evaluated THV; however, the incidence of paravalvular leakage differed significantly between the devices implanted.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Ecocardiografia / Tomografia Computadorizada Multidetectores / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Eur Heart J Cardiovasc Imaging Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Ecocardiografia / Tomografia Computadorizada Multidetectores / Substituição da Valva Aórtica Transcateter Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: Eur Heart J Cardiovasc Imaging Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Alemanha