Your browser doesn't support javascript.
loading
The use of latex foley catheter in repair of hypospadias the most common seen congenital penile anomaly.
Polat, Haci; Yucel, Mehmet Ozgur; Cift, Ali; Gok, Alper; Benlioglu, Can; Lok, Ugur; Gulacti, Umut.
Afiliação
  • Polat H; Department of Urology, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Yucel MO; Department of Urology, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Cift A; Department of Urology, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Gok A; Department of Urology, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Benlioglu C; Department of Urology, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Lok U; Department of Emergency Medicine, Medical Faculty, Adiyaman University Adiyaman, Turkey.
  • Gulacti U; Department of Emergency Medicine, Medical Faculty, Adiyaman University Adiyaman, Turkey.
Int J Clin Exp Med ; 8(8): 13421-3, 2015.
Article em En | MEDLINE | ID: mdl-26550278
ABSTRACT

OBJECTIVE:

Hypospadias is the most common congenital penile anomaly occurring in 1/300 live births. Various surgery techniques are used in repair of hypospadias. Infant and children with hypospadias are usually admitted to emergency services by worried their parents for the first time. TIP urethroplasty is widely used in the repair of hypospadias, but the use of urethral catheters is still a matter for discussion. Herein, we described our experiences with the use of an unsutured latex foley catheter placed in the glans for 24 to 48 hours.

METHODS:

A retrospective chart review was performed on 38 patients who underwent Tubularized incised plate (TIP) hypospadias repair from 2009 to 2011. Of these, 35 patients who had two-way latex Foley catheters placed for 24 h to 48 hands were followed for at least 12 month.

RESULTS:

Excellent cosmetic results were obtained in all patients. Urinary tract infection developed in two patients (5.7%). one patient (2.8%) who had mild urethral repair breakdown was repaired in the office environment.

CONCLUSION:

We observed very low complication rates in application of a two-way latex Foley catheter in hypospadias surgery and found that this method can be used safely. Moreover, the catheter can be used for traction purposes during the procedure. At the end of the 24 to 48 h period, removal of the two-way latex urethral catheter with balloon does not harm the urethral repair. To reach a definite conclusion, larger studies are needed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Int J Clin Exp Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Int J Clin Exp Med Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia