Your browser doesn't support javascript.
loading
Decrease in B-Type Natriuretic Peptide Levels and Successful Catheter Ablation for Atrial Fibrillation in Patients with Heart Failure.
Yanagisawa, Satoshi; Inden, Yasuya; Kato, Hiroyuki; Fujii, Aya; Mizutani, Yoshiaki; Ito, Tadahiro; Kamikubo, Yosuke; Kanzaki, Yasunori; Hirai, Makoto; Murohara, Toyoaki.
Afiliação
  • Yanagisawa S; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Inden Y; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Kato H; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Fujii A; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Mizutani Y; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Ito T; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Kamikubo Y; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Kanzaki Y; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Hirai M; Department of Cardiology, Nagoya University Graduate School of Health Science, Nagoya, Japan.
  • Murohara T; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Pacing Clin Electrophysiol ; 39(3): 225-34, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26596862
ABSTRACT

BACKGROUND:

Little is known about the association between B-type natriuretic peptide (BNP) levels and catheter ablation of atrial fibrillation (AF) in patients with heart failure. This study aimed to examine the impact of elimination of AF by catheter ablation on BNP levels in patients with left ventricular systolic dysfunction.

METHODS:

Fifty-four AF patients with left ventricular ejection fraction (LVEF) ≤ 50%, who underwent radiofrequency catheter ablation therapy of AF, were included. BNP sampling was performed at baseline, 3 days, and 1 month after ablation.

RESULTS:

After a follow-up period of 6 months, the BNP levels decreased significantly in the nonrecurrence group (n = 35; median 126.3 [interquartile 57.2-206.5] pg/mL, 63.5 [23.9-180.2] pg/mL, and 45.9 [21.9-160.3] pg/mL, P < 0.001, respectively), but not in the recurrence group (n = 19; 144.7 [87.1-217.3] pg/mL, 88.8 [12.9-213.2] pg/mL, and 118.5 [51.6-298.2] pg/mL, P = 0.368, respectively). The patients in the nonrecurrence group had a higher percentage relative reduction in BNP levels from baseline to 1 month after ablation than those in the recurrence group (56.5 [-9.0-77.4]% vs -2.4 [-47.1-60.9]%, P = 0.027). Additionally, a relative reduction in BNP levels significantly correlated with an increase in LVEF after ablation (r = 0.486, P < 0.001).

CONCLUSIONS:

Plasma BNP levels decreased significantly with successful catheter ablation of AF in patients with impaired LVEF. The decrease in BNP levels might be associated with early recovery of cardiac function and subsequent maintenance of sinus rhythm at follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Peptídeo Natriurético Encefálico / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Peptídeo Natriurético Encefálico / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Japão