Dental unit water treatment with hydrogen peroxide and monovalent silver ions artificially contaminated with freshly isolated pathogens.
Petti, S; Polimeni, A; Allen, M J.
Afiliação
  • Petti S; Department of Public Health and Infectious Diseases, Sapienza University, Rome, Italy.
  • Polimeni A; Department of Dental and Maxillofacial Sciences, Sapienza University, Rome, Italy.
  • Allen MJ; Water Research Foundation (retired), Denver, CO, USA.
Ann Ig ; 27(6): 789-98, 2015.
Article em En | MEDLINE | ID: mdl-26835793
ABSTRACT

BACKGROUND:

Dental unit water (DUW) could be contaminated by human pathogens coming from biological fluids penetrated during patient treatment and by opportunistic pathogens detached from aquatic biofilm. These microorganisms could be spread to following patients. We tested the disinfectant activity of hydrogen peroxide and monovalent silver ions (H(2)O(2)-Ag(+)) into DUW artificially contaminated with freshly isolated pathogens.

METHODS:

The tested microorganisms were Staphylococcus aureus, Enterococcus faecalis, Candida albicans, Pseudomonas aeruginosa, Legionella pneumophila, Mycobacterium chelonae, non-pathogenic Bacillus clausii spores. Bacterial suspensions were inoculated into the waterlines of pre-sterilized dental turbines. The test-turbines were connected to DUW and contaminated water was treated for 10 minutes with H(2)O(2)-Ag(+)-based disinfectant (H(2)O(2) 3% v/v, Ag(+) 0.001% w/v). The control-turbines were left untreated. Turbines were washed with sterile hard water used to assess the residual bacterial loads (expressed in colony forming units -cfu). Each strain was tested five times and the mean log loads were assessed. Following the European Standardization Committee, the disinfectant activity was evaluated as mean log load reduction, that is, the difference between the mean log load detected on the control-turbines and the mean log load detected on the test-turbines.

RESULTS:

Mean bacterial loads detected on the control-turbines ranged between 105-107 cfu. The mean log load reductions resulted 7.5 log cfu for S. aureus, E. faecalis, P. aeruginosa, 6.3 for C. albicans, 5.4 for L. pneumophila, 5.3 for M. chelonae, 2.9 for B. clausii spores.

CONCLUSIONS:

DUW disinfection with H(2)O(2)-Ag(+) could help minimize the risk that planktonic pathogens are spread to patients during dental treatment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Microbiologia da Água / Desinfecção / Desinfetantes de Equipamento Odontológico / Controle de Infecções Dentárias / Equipamentos Odontológicos / Peróxido de Hidrogênio Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Ann Ig Assunto da revista: MICROBIOLOGIA / SAUDE PUBLICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prata / Microbiologia da Água / Desinfecção / Desinfetantes de Equipamento Odontológico / Controle de Infecções Dentárias / Equipamentos Odontológicos / Peróxido de Hidrogênio Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Ann Ig Assunto da revista: MICROBIOLOGIA / SAUDE PUBLICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália