Your browser doesn't support javascript.
loading
The use of wearable cardioverter-defibrillators in Europe: results of the European Heart Rhythm Association survey.
Lenarczyk, Radoslaw; Potpara, Tatjana S; Haugaa, Kristina H; Hernández-Madrid, Antonio; Sciaraffia, Elena; Dagres, Nikolaos.
Afiliação
  • Lenarczyk R; Department of Cardiology, Congenital Heart Disease and Electrotherapy, Silesian Medical University, Silesian Center for Heart Disease, Curie-Sklodowskiej 9, Zabrze 41-800, Poland radle@poczta.onet.pl.
  • Potpara TS; School of Medicine, Belgrade University, Cardiology Clinic, Clinical Centre of Serbia, Belgrade, Serbia.
  • Haugaa KH; Department of Cardiology, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
  • Hernández-Madrid A; Cardiology Department, Ramón y Cajal Hospital, Madrid 28034, Spain.
  • Sciaraffia E; Department of Cardiology, Institution of Medical Science, Uppsala University, Uppsala 75185, Sweden.
  • Dagres N; Department of Electrophysiology, Heart Center Leipzig, Leipzig, Germany.
Europace ; 18(1): 146-50, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26842735
ABSTRACT
The aim of this European Heart Rhythm Association (EHRA) survey was to collect data on the use of wearable cardioverter-defibrillators (WCDs) among members of the EHRA electrophysiology research network. Of the 50 responding centres, 23 (47%) reported WCD use. Devices were fully reimbursed in 17 (43.6%) of 39 respondents, and partially reimbursed in 3 centres (7.7%). Eleven out of 20 centres (55%) reported acceptable patients' compliance (WCD worn for >90% of time). The most common indications for WCD (8 out of 10 centres; 80%) were covering the period until re-implantation of ICD explanted due to infection, in patients with left ventricular impairment due to myocarditis or recent myocardial infarction and those awaiting heart transplantation. Patient life expectancy of <12 months and poor compliance were the most commonly reported contraindications for WCD (24 of 46 centres, 52.2%). The major problems encountered by physicians managing patients with WCD were costs (8 of 18 centres, 44.4%), non-compliance, and incorrect use of WCD. Four of 17 centres (23.5%) reported inappropriate WCD activations in <5% of patients. The first shock success rate in terminating ventricular arrhythmias was 95-100% in 6 of 15 centres (40%), 85-95% in 4 (26.7%), 75-85% in 2 (13.3%), and <75% in 3 centres (20%). The survey has shown that the use of WCD in Europe is still restricted and depends on reimbursement. Patients' compliance remains low. Heterogeneity of indications for WCD among centres underscores the need for further research and a better definition of indications for WCD in specific patient groups.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia Ambulatorial / Cooperação do Paciente / Morte Súbita Cardíaca / Desfibriladores Tipo de estudo: Clinical_trials / Prevalence_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletrocardiografia Ambulatorial / Cooperação do Paciente / Morte Súbita Cardíaca / Desfibriladores Tipo de estudo: Clinical_trials / Prevalence_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: Europace Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Polônia