The Crossmatch/Issue Ratio: Use of a Novel Quality Indicator and Results of an International Survey on RBC Crossmatching and Issuing Practices.
Yazer, Mark H; Alcantara, Ramir; Beizai, Pouneh; Draper, Nicole L; Harm, Sarah K; Kutner, Jose M; Lin, David; Poglod, Ryszard; Rogers, Thomas S; Sørensen, Claess H; Sprogøe, Ulrik; Welbig, Julie; Yuen, Joyce; Ziman, Alyssa.
Afiliação
  • Yazer MH; From the University of Pittsburgh, Pittsburgh, PA The Institute for Transfusion Medicine, Pittsburgh, PA myazer@itxm.org.
  • Alcantara R; Health Sciences Authority Blood Services Group, Singapore.
  • Beizai P; Department of Pathology and Laboratory Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA.
  • Draper NL; University of Colorado Hospital, Aurora.
  • Harm SK; University of Vermont Medical Center, Burlington.
  • Kutner JM; Hospital Israelita Albert Einstein, São Paulo, Brazil.
  • Lin D; Lin Shin Hospital, Taichung City, Taiwan.
  • Poglod R; Institute of Hematology and Transfusion Medicine, Warsaw, Poland.
  • Rogers TS; University of Vermont Medical Center, Burlington.
  • Sørensen CH; Southern Danish Transfusion Service, Odense, Denmark.
  • Sprogøe U; Southern Danish Transfusion Service, Odense, Denmark.
  • Welbig J; University of Minnesota Medical Center, Minneapolis.
  • Yuen J; Tan Tock Seng Hospital, Singapore.
  • Ziman A; Department of Pathology and Laboratory Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA.
Am J Clin Pathol ; 146(2): 238-43, 2016 Aug.
Article em En | MEDLINE | ID: mdl-27473742
ABSTRACT

OBJECTIVES:

To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio.

METHODS:

An electronic survey was disseminated to hospital transfusion services collecting details about RBC crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio.

RESULTS:

Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents, and the mean ± SD was 1.30 ± 0.34. There was no difference in C/I ratios between services that use the electronic or serologic crossmatch techniques (P = .49). The ratio was the same at the four sites that crossmatch RBCs at the time of issue compared with the time of order receipt (mean ± SD, 1.11 ± 0.09 vs. 1.35 ± 0.36, respectively; P = .19).

CONCLUSIONS:

Electronic crossmatching is common, and the C/I ratio can be an indicator of efficiency.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tipagem e Reações Cruzadas Sanguíneas / Sistemas Computadorizados de Registros Médicos / Transfusão de Eritrócitos Limite: Humans Idioma: En Revista: Am J Clin Pathol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Panamá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tipagem e Reações Cruzadas Sanguíneas / Sistemas Computadorizados de Registros Médicos / Transfusão de Eritrócitos Limite: Humans Idioma: En Revista: Am J Clin Pathol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Panamá