Your browser doesn't support javascript.
loading
Determination of propranolol and carvedilol in urine samples using a magnetic polyamide composite and LC-MS/MS.
Ballesteros-Esteban, Tamara; Reyes-Gallardo, Emilia M; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel.
Afiliação
  • Ballesteros-Esteban T; Department of Analytical Chemistry, Institute of Fine Chemistry & Nanochemistry, Marie Curie Building, Campus of Rabanales, University of Córdoba, 14071 Córdoba, Spain.
  • Reyes-Gallardo EM; Department of Analytical Chemistry, Institute of Fine Chemistry & Nanochemistry, Marie Curie Building, Campus of Rabanales, University of Córdoba, 14071 Córdoba, Spain.
  • Lucena R; Department of Analytical Chemistry, Institute of Fine Chemistry & Nanochemistry, Marie Curie Building, Campus of Rabanales, University of Córdoba, 14071 Córdoba, Spain.
  • Cárdenas S; Department of Analytical Chemistry, Institute of Fine Chemistry & Nanochemistry, Marie Curie Building, Campus of Rabanales, University of Córdoba, 14071 Córdoba, Spain.
  • Valcárcel M; Department of Analytical Chemistry, Institute of Fine Chemistry & Nanochemistry, Marie Curie Building, Campus of Rabanales, University of Córdoba, 14071 Córdoba, Spain.
Bioanalysis ; 8(20): 2115-23, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27593542
ABSTRACT

AIM:

ß-blockers are compounds that bind with adrenoreceptors hindering their interaction with adrenalin and noradrenalin. They are clinically relevant and they are also used in some sport as doping agents.

RESULTS:

A new method based on the combination of dispersive micro-solid phase extraction and LC-MS/MS has been developed to determine propranolol and carvedilol in urine samples. For this purpose a magnetic-polyamide composite is synthesized and used as sorbent. Working under the optimum conditions, the method provides limits of detection and quantification in the range of 0.1-0.15 µg/l and 0.3-0.5 µg/l, for carvedilol and propranolol, respectively. The precision, expressed as RSD, was better than 9.6% and the relative recoveries varied between 73.7 and 81.3%.

CONCLUSION:

The methodology is appropriate for the determination of ß-blockers in urine samples at the low microgram per liter range for therapeutic purposes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propanolaminas / Propranolol / Carbazóis / Cromatografia Líquida de Alta Pressão / Urinálise / Antagonistas Adrenérgicos beta / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propanolaminas / Propranolol / Carbazóis / Cromatografia Líquida de Alta Pressão / Urinálise / Antagonistas Adrenérgicos beta / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Bioanalysis Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha