Your browser doesn't support javascript.
loading
High-density collagen patch prevents stricture after endoscopic circumferential submucosal dissection of the esophagus: a porcine model.
Aoki, Shigehisa; Sakata, Yasuhisa; Shimoda, Ryo; Takezawa, Toshiaki; Oshikata-Miyazaki, Ayumi; Kimura, Hiromi; Yamamoto, Mihoko; Iwakiri, Ryuichi; Fujimoto, Kazuma; Toda, Shuji.
Afiliação
  • Aoki S; Department of Pathology and Microbiology, Faculty of Medicine, Saga University, Saga, Japan.
  • Sakata Y; Department of Internal Medicine & Gastrointestinal Endoscopy, Faculty of Medicine, Saga University, Saga, Japan.
  • Shimoda R; Department of Internal Medicine & Gastrointestinal Endoscopy, Faculty of Medicine, Saga University, Saga, Japan.
  • Takezawa T; Division of Biotechnology, Institute of Agrobiological Sciences, National Agriculture and Food Research Organization, Ibaraki, Japan.
  • Oshikata-Miyazaki A; Division of Biotechnology, Institute of Agrobiological Sciences, National Agriculture and Food Research Organization, Ibaraki, Japan.
  • Kimura H; Department of Pathology and Microbiology, Faculty of Medicine, Saga University, Saga, Japan.
  • Yamamoto M; Department of Pathology and Microbiology, Faculty of Medicine, Saga University, Saga, Japan.
  • Iwakiri R; Department of Internal Medicine & Gastrointestinal Endoscopy, Faculty of Medicine, Saga University, Saga, Japan.
  • Fujimoto K; Department of Internal Medicine & Gastrointestinal Endoscopy, Faculty of Medicine, Saga University, Saga, Japan.
  • Toda S; Department of Pathology and Microbiology, Faculty of Medicine, Saga University, Saga, Japan.
Gastrointest Endosc ; 85(5): 1076-1085, 2017 May.
Article em En | MEDLINE | ID: mdl-27751874
ABSTRACT
BACKGROUND AND

AIMS:

Extensive excision of the esophageal mucosa by endoscopic submucosal dissection (ESD) frequently evokes a luminal stricture. This study aimed to determine the efficacy of a high-density collagen patch for the prevention of esophageal stricture in extensive ESD.

METHODS:

Six pigs underwent circumferential esophageal ESD under general anesthesia. In 3 pigs, artificial ulcers were covered by 2 collagen patches. The other 3 pigs underwent circumferential ESD only.

RESULTS:

The 2 collagen patches were settled onto the ulcer surface using a general endoscope and instruments. The collagen patch-treated group showed significantly better patency rates on both the oral and anal sides of the wound area compared with the control group at day 14. The mucosal re-epithelization ratio was significantly promoted, and the extent of mucosal inflammation and fibrosis was significantly decreased with the collagen patch treatment in the wound area. The frequency of cells positive α-smooth muscle actin was significantly reduced in the collagen patch-treated group compared with the control group.

CONCLUSIONS:

We have established a high-density collagen device that can reduce the esophageal stricture associated with extensive ESD. This easy-to-handle device would be useful during superficial esophageal cancer treatment by ESD.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Cicatrização / Colágeno / Esofagoscopia / Estenose Esofágica / Esôfago / Mucosa Esofágica / Ressecção Endoscópica de Mucosa Limite: Animals Idioma: En Revista: Gastrointest Endosc Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Cicatrização / Colágeno / Esofagoscopia / Estenose Esofágica / Esôfago / Mucosa Esofágica / Ressecção Endoscópica de Mucosa Limite: Animals Idioma: En Revista: Gastrointest Endosc Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão