Your browser doesn't support javascript.
loading
Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST).
Xu, Z; Wu, Z W; Gao, W; Chen, Y J; Wu, C R; Zhang, L; Huang, J; Chang, J F; Yao, X J; Gao, W; Zhang, P F; Jin, Z; Hou, Y M; Guo, H Y.
Afiliação
  • Xu Z; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Wu ZW; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Gao W; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Chen YJ; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Wu CR; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Zhang L; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Huang J; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Chang JF; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Yao XJ; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Gao W; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Zhang PF; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Jin Z; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Hou YM; Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031, China.
  • Guo HY; General Atomics, San Diego, California 92186-5608, USA.
Rev Sci Instrum ; 87(11): 11D429, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27910502
ABSTRACT
A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including Dα (656.1 nm), Dγ (433.9 nm), He ii (468.5 nm), Li i (670.8 nm), Li ii (548.3 nm), C iii (465.0 nm), O ii (441.5 nm), Mo i (386.4 nm), W i (400.9 nm), and visible bremsstrahlung radiation (538.0 nm) are monitored with corresponding wavelength filters. All these multi-channel signals are digitized at up to 200 kHz simultaneously. This diagnostic plays a crucial role in studying edge localized modes and H-mode plasmas, due to the high temporal resolution and spatial resolution that have been designed into it.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China