Your browser doesn't support javascript.
loading
Fluoroscopic-guided stent placement in failed tentative endoscopic approaches to malignant gastroduodenal obstructions.
Kim, Soo Hwan; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Cho, Young Chul; Shin, Ji Hoon; Kim, Jin Hyoung.
Afiliação
  • Kim SH; 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Song HY; 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Park JH; 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Zhou WZ; 2 Biomedical Engineering Research Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Cho YC; 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Shin JH; 3 Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China.
  • Kim JH; 1 Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Acta Radiol ; 58(8): 959-963, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28084810
ABSTRACT
Background Fluoroscopic or endoscopic placement of metallic stents is used as a safe, non-surgical, palliative treatment option for malignant gastroduodenal obstructions. However, endoscopic stent placement is not always feasible, due to the tight or tortuous stricture of the obstructed area and insufficient visualization of the stomach due to remnant food material. Purpose To assess the technical feasibility and clinical outcomes of fluoroscopic-guided stent placement in malignant gastroduodenal obstructions following the technical failure of endoscopic stent placement. Material and Methods In all, 19 patients (14 men, 5 women; age range, 36-85 years) were referred due to technical failures of tentative endoscopic stent placement. Indications were failure to pass the guide wire through the obstruction (n = 13), failure to reach the stricture lesion due to short endoscope (n = 5), and acute angulation of the stricture lesion (n = 1). Data were retrospectively collected regarding the technical and clinical success of the fluoroscopy, the dysphagia score before and after stent placement, and major complications and their management. Results Fluoroscopic stent placement was technically successful in 15/19 patients (79%). Failures were due to complete obstruction (n = 3) and acute angulation of the stricture lesion (n = 1). Clinical success was achieved in all 15 patients with successful stent placement. The dysphagia score significantly improved after stent placement ( P < 0.001). Complications occurred in 4/15 patients (27%), including tumor overgrowth (n = 2), stent collapse (n = 1), and jaundice (n = 1). Conclusion Fluoroscopic stent placement in malignant gastroduodenal obstructions following a technical failure of endoscopic stent placement is technically feasible and has an acceptable clinical outcome.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Radiografia Intervencionista / Stents / Obstrução da Saída Gástrica Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Radiografia Intervencionista / Stents / Obstrução da Saída Gástrica Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2017 Tipo de documento: Article