Your browser doesn't support javascript.
loading
The value of visual field testing in the era of advanced imaging: clinical and psychophysical perspectives.
Phu, Jack; Khuu, Sieu K; Yapp, Michael; Assaad, Nagi; Hennessy, Michael P; Kalloniatis, Michael.
Afiliação
  • Phu J; Centre for Eye Health, The University of New South Wales, Kensington, New South Wales, Australia.
  • Khuu SK; School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia.
  • Yapp M; School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia.
  • Assaad N; Centre for Eye Health, The University of New South Wales, Kensington, New South Wales, Australia.
  • Hennessy MP; School of Optometry and Vision Science, The University of New South Wales, Kensington, New South Wales, Australia.
  • Kalloniatis M; Centre for Eye Health, The University of New South Wales, Kensington, New South Wales, Australia.
Clin Exp Optom ; 100(4): 313-332, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28640951
ABSTRACT
White-on-white standard automated perimetry (SAP) is widely used in clinical and research settings for assessment of contrast sensitivity using incremental light stimuli across the visual field. It is one of the main functional measures of the effect of disease upon the visual system. SAP has evolved over the last 40 years to become an indispensable tool for comprehensive assessment of visual function. In modern clinical practice, a range of objective measurements of ocular structure, such as optical coherence tomography, have also become invaluable additions to the arsenal of the ophthalmic examination. Although structure-function correlation is a highly desirable determinant of an unambiguous clinical picture for a patient, in practice, clinicians are often faced with discordance of structural and functional results, which presents them with a challenge. The construction principles behind the development of SAP are used to discuss the interpretation of visual fields, as well as the problem of structure-function discordance. Through illustrative clinical examples, we provide useful insights to assist clinicians in combining a range of clinical results obtained from SAP and from advanced imaging techniques into a coherent picture that can help direct clinical management.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Psicofísica / Transtornos da Visão / Diagnóstico por Imagem / Sensibilidades de Contraste / Campos Visuais / Testes de Campo Visual Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Clin Exp Optom Assunto da revista: OPTOMETRIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Psicofísica / Transtornos da Visão / Diagnóstico por Imagem / Sensibilidades de Contraste / Campos Visuais / Testes de Campo Visual Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Clin Exp Optom Assunto da revista: OPTOMETRIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália