Your browser doesn't support javascript.
loading
Validation of biplane high-speed fluoroscopy combined with two different noninvasive tracking methodologies for measuring in vivo distal limb kinematics of the horse.
Geiger, S M; Reich, E; Böttcher, P; Grund, S; Hagen, J.
Afiliação
  • Geiger SM; Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, Leipzig, Germany.
  • Reich E; Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, Leipzig, Germany.
  • Böttcher P; Small Animal Clinic, Department of Veterinary Medicine, Freie Universität, Berlin, Berlin, Germany.
  • Grund S; Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, Leipzig, Germany.
  • Hagen J; Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, Leipzig, Germany.
Equine Vet J ; 50(2): 261-269, 2018 Mar.
Article em En | MEDLINE | ID: mdl-28703332
ABSTRACT
REASON FOR PERFORMING STUDY Biplane high-speed fluoroscopy is a new method for gait analysis of the equine distal extremity. This is the first study validating the noninvasive tracking possibilities (Autoscoping and Scientific Rotoscoping) taking equine anatomy into account.

OBJECTIVES:

To determine the resolution with which Autoscoping and Scientific Rotoscoping depict motion of the equine phalanges in comparison to the invasive gold standard marker-based registration. STUDY

DESIGN:

Comparative ex vivo study.

METHODS:

In 5 distal extremities of slaughtered ponies, 3 or 4 tantalum beads with 1 mm diameter were implanted in each of the proximal, middle and distal phalangeal bones. Three-dimensional models of the bones were reconstructed using computed tomographic data (120 kV, 50 mA, slice thickness 1 mm, increment 0.5). The beads were digitally removed from the bone models. Biplane fluoroscopic videos were taken at 69.5 ± 3.5 kV, 102.5 ± 22.5 mA, 500 frames/s and 0.5 ms shutter speed. The 5 specimens were moved in the trial field of the biplane fluoroscopic setup in a step-like motion (simulation of landing, main stance phase, lift-off). Marker-based registration, Autoscoping and Scientific Rotoscoping were carried out. For statistical analysis agreement was computed as percentiles, mean and s.d.

RESULTS:

The medians of Scientific Rotoscoping ranged from 0.16 to 0.66 mm in translations and 0.43 to 2.78° in rotations, while values for Autoscoping were 0.13-0.70 mm and 0.28-2.39° respectively. With 2 exceptions, all differences between methods were statistically significant. Scientific Rotoscoping is more time efficient than Autoscoping and results in smaller maximum errors. MAIN

LIMITATIONS:

The experimental set-up was specifically designed to accommodate in vivo requirements. Autoscoping was not manually corrected but rather expected to work automatically.

CONCLUSIONS:

It is possible to noninvasively apply both Autoscoping and Scientific Rotoscoping for gait analysis of the equine phalanges with high precision. The summary is available in Chinese - see supporting information.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Membro Anterior / Cavalos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Equine Vet J Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Membro Anterior / Cavalos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Equine Vet J Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha