Your browser doesn't support javascript.
loading
Advanced online mass spectrometry detection of proteins separated by capillary isoelectric focusing after sequential injection.
Páger, Csilla; Biherczová, Nikoleta; Ligetvári, Roland; Berkics, Balázs Viktor; Pongrácz, Tamás; Sándor, Viktor; Bufa, Anita; Poór, Viktória; Vojs Stanová, Andrea; Kilár, Ferenc.
Afiliação
  • Páger C; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Biherczová N; Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Bratislava, Slovak Republic.
  • Ligetvári R; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Berkics BV; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Pongrácz T; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Sándor V; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Bufa A; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Poór V; Institute of Bioanalysis and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
  • Vojs Stanová A; Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University in Bratislava, Bratislava, Slovak Republic.
  • Kilár F; University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Vodnany, Czech Republic.
J Sep Sci ; 40(24): 4825-4834, 2017 Dec.
Article em En | MEDLINE | ID: mdl-29064636
ABSTRACT
Capillary isoelectric focusing hyphenated with mass spectrometry detection, following the sequential injection of the carrier ampholytes and the sample zone, is highly efficient for the characterization of proteins. The main advantage of the sequential injection protocol is that ampholytes, with pH ranges, which are not supposed to cover the isoelectric points of the sample components, can be used for separation. The method then allows online mass spectrometry detection of separated analytes either in the absence (substances that have left the pH gradient) or in the presence of low-level ampholytes (substances that are migrating within the pH gradient). The appearance of the substances within, or outside the pH gradient depends on, e.g., the composition of the ampholytes (broad or narrow pH range) or on the composition of electrolyte solutions. The experiments performed in coated capillaries (with polyvinyl alcohol or with polyacrylamide) show that the amount and the injection length of the ampholytes influence the length of the pH gradient formed in the capillary.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteínas / Eletroforese Capilar / Focalização Isoelétrica Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteínas / Eletroforese Capilar / Focalização Isoelétrica Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Sep Sci Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Hungria