ABSTRACT

INTRODUCTION:

The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. AREAS COVERED Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. EXPERT COMMENTARY After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lágrimas / Tomografia de Coerência Óptica / Olho Limite: Animals / Humans Idioma: En Revista: Expert Rev Med Devices Assunto da revista: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lágrimas / Tomografia de Coerência Óptica / Olho Limite: Animals / Humans Idioma: En Revista: Expert Rev Med Devices Assunto da revista: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Espanha