Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?
Brüggemann, Anders; Mallmin, Hans; Hailer, Nils P.
Afiliação
  • Brüggemann A; a Department of Surgical Sciences/Section of Orthopedics , Uppsala University , Uppsala , Sweden.
  • Mallmin H; a Department of Surgical Sciences/Section of Orthopedics , Uppsala University , Uppsala , Sweden.
  • Hailer NP; a Department of Surgical Sciences/Section of Orthopedics , Uppsala University , Uppsala , Sweden.
Acta Orthop ; 89(2): 156-162, 2018 Apr.
Article em En | MEDLINE | ID: mdl-29400106
ABSTRACT
Background and purpose - Dual-mobility cups (DMCs) reduce the risk of dislocation and porous tantalum (TM) shells show favorable osseointegration after acetabular revision surgery, yet the combination of these implants has not been studied. We hypothesized that (1) cementing a DMC into a TM shell decreases the risk of dislocation; (2) DMCs cemented into TM shells are not at greater risk of re-revision; (3) liberation of tantalum ions is marginal after use of this combined technique. Patients and methods - We investigated the outcome in 184 hips (184 patients) after acetabular revision surgery with TM shells, fitted either with DMCs (n = 69), or with standard poly-ethylene (PE) liners (n = 115). Chart follow-up was complete for all patients, and the occurrence of dislocations and re-revisions was recorded. 20 were deceased, 50 were unable to attend follow-up, leaving 114 for assessment of hip function after 4.9 (0.5-8.9) years, radiographs were obtained in 99, and tantalum concentrations in 84 patients. Results - 1 patient with a DMC had a dislocation, whereas 14 patients with PE liners experienced at least 1 dislocation. 11 of 15 re-revisions in the PE group were necessitated by dislocations, whereas none of the 2 re-revisions in the DMC group was performed for this reason. Hence, dislocation-free survival after 4 years was 99% (95% CI 96-100) in the DMC group, whereas it was 88% (CI 82-94, p = 0.01) in the PE group. We found no radiographic signs of implant failure in any patient. Mean tantalum concentrations were 0.1 µl/L (CI 0.05-0.2) in the DMC group and 0.1 µg/L (CI 0.05-0.2) in the PE group. Interpretation - Cementing DMCs into TM shells reduces the risk of dislocation after acetabular revision surgery without jeopardizing overall cup survival, and without enhancing tantalum release.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Desenho de Prótese / Tantálio / Artroplastia de Quadril / Luxações Articulares / Prótese de Quadril Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Orthop Assunto da revista: ORTOPEDIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Desenho de Prótese / Tantálio / Artroplastia de Quadril / Luxações Articulares / Prótese de Quadril Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Orthop Assunto da revista: ORTOPEDIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Suécia