Your browser doesn't support javascript.
loading
Point-of-Care Determination of Acetaminophen Levels with Multi-Hydrogen Bond Manipulated Single-Molecule Recognition (eMuHSiR).
Zhang, Yan; Huang, Zhongyuan; Wang, Letao; Wang, Chunming; Zhang, Changde; Wiese, Tomas; Wang, Guangdi; Riley, Kevin; Wang, Zhe.
Afiliação
  • Zhang Y; Department of Chemistry , Xavier University of Louisiana , New Orleans 70125 , United States.
  • Huang Z; College of Chemistry and Chemical Engineering , Lanzhou University , Lanzhou 730000 , China.
  • Wang L; Department of Chemistry , Xavier University of Louisiana , New Orleans 70125 , United States.
  • Wang C; College of Chemistry and Chemical Engineering , Xinyang Normal University , Xinyang 464000 , China.
  • Zhang C; College of Chemistry and Chemical Engineering , Lanzhou University , Lanzhou 730000 , China.
  • Wiese T; College of Chemistry and Chemical Engineering , Lanzhou University , Lanzhou 730000 , China.
  • Wang G; Department of Chemistry , Xavier University of Louisiana , New Orleans 70125 , United States.
  • Riley K; College of Pharmacy , Xavier University of Louisiana , New Orleans 70125 , United States.
  • Wang Z; Department of Chemistry , Xavier University of Louisiana , New Orleans 70125 , United States.
Anal Chem ; 90(7): 4733-4740, 2018 04 03.
Article em En | MEDLINE | ID: mdl-29543434
ABSTRACT
This work aims to face the challenge of monitoring small molecule drugs accurately and rapidly for point-of-care (POC) diagnosis in current clinical settings. Overdose of acetaminophen (AP), a commonly used over the counter (OTC) analgesic drug, has been determined to be a major cause of acute liver failure in the US and the UK. However, there is no rapid and accurate detection method available for this drug in the emergency room. The present study examined an AP sensing strategy that relies on a previously unexplored strong interaction between AP and the arginine (Arg) molecule. It was found that as many as 4 hydrogen bonds can be formed between one Arg molecule and one AP molecule. By taking advantages of this structural selectivity and high tenability of hydrogen bonds, Arg, immobilized on a graphene surface via electrostatic interactions, was utilized to structurally capture AP. Interestingly, bonded AP still remained the perfect electrochemical activities. The extent of Arg-AP bonds was quantified using a newly designed electrochemical (EC) sensor. To verify the feasibility of this novel assay, based on multihydrogen bond manipulated single-molecule recognition (eMuHSiR), both pharmaceutical and serum sample were examined. In commercial tablet measurement, no significant difference was seen between the results of eMuHSiR and other standard methods. For measuring AP concentration in the mice blood, the substances in serum, such as sugars and fats, would not bring any interference to the eMuHSiR in a wide concentration range. This eMuHSiR method opens the way for future development of small molecule detection for the POC testing.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arginina / Sistemas Automatizados de Assistência Junto ao Leito / Acetaminofen Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arginina / Sistemas Automatizados de Assistência Junto ao Leito / Acetaminofen Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos