Your browser doesn't support javascript.
loading
Quantitative Bioimaging of Platinum via Online Isotope Dilution-Laser Ablation-Inductively Coupled Plasma Mass Spectrometry.
Bauer, Oliver Bolle; Köppen, Christina; Sperling, Michael; Schurek, Hans-Joachim; Ciarimboli, Giuliano; Karst, Uwe.
Afiliação
  • Bauer OB; Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany.
  • Köppen C; Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany.
  • Sperling M; Westfälische Wilhelms-Universität Münster , Institute of Inorganic and Analytical Chemistry , Corrensstraße 30 , 48149 Münster , Germany.
  • Schurek HJ; European Virtual Institute for Speciation Analysis (EVISA) , Mendelstraße 11 , 48149 Münster , Germany.
  • Ciarimboli G; Department of Experimental Nephrology , University Hospital of Münster , Albert-Schweitzer-Campus 1 , 48149 Münster , Germany.
  • Karst U; Department of Experimental Nephrology , University Hospital of Münster , Albert-Schweitzer-Campus 1 , 48149 Münster , Germany.
Anal Chem ; 90(11): 7033-7039, 2018 06 05.
Article em En | MEDLINE | ID: mdl-29741357
ABSTRACT
A new calibration strategy for elemental bioimaging based on online isotope dilution analysis (IDA) and laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) was developed and applied for the quantification of platinum in rat kidney tissues. A dry 194Pt spike aerosol was added in a post-cell setup, and the natural 194Pt/195Pt isotope ratio of the sample aerosol from laser ablation was changed accordingly. Spike mass flow determination was carried out based on reversed IDA using a reference standard. Quantitative data obtained by the new approach correlated well with those obtained by external calibration when analyzing parallel tissue slices of rat kidney from cisplatin perfusion studies. The novel quantification approach is traceable to SI units, as IDA is an definitive method. Signal drifts are compensated as the second isotope acts as an internal standard.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Técnica de Diluição de Radioisótopos / Rim Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Platina / Técnica de Diluição de Radioisótopos / Rim Limite: Animals Idioma: En Revista: Anal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha