Your browser doesn't support javascript.
loading
Effect of titanium surface functionalization with bioactive glass on osseointegration: An experimental study in dogs.
Soares, Priscilla Barbosa Ferreira; Moura, Camilla Christian Gomes; Chinaglia, Clever Ricardo; Zanotto, Edgar Dutra; Zanetta-Barbosa, Darceny; Stavropoulos, Andreas.
Afiliação
  • Soares PBF; School of Dentistry, Universidade Federal de Uberlândia, Uberlândia, Brazil.
  • Moura CCG; School of Dentistry, Universidade Federal de Uberlândia, Uberlândia, Brazil.
  • Chinaglia CR; Department of Materials Engineering (DEMa), Federal University of São Carlos, São Carlos, Brazil.
  • Zanotto ED; Department of Materials Engineering (DEMa), Federal University of São Carlos, São Carlos, Brazil.
  • Zanetta-Barbosa D; School of Dentistry, Universidade Federal de Uberlândia, Uberlândia, Brazil.
  • Stavropoulos A; Department of Periodontology, Faculty of Odontology, Malmö University, Malmö, Sweden.
Clin Oral Implants Res ; 29(11): 1120-1125, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30264907
ABSTRACT

PURPOSE:

The purpose of this study was to evaluate the effect of surface functionalization with bioactive glass BSF18 on the osseointegration of sandblasted and dual acid-etched surface (AE) implants. METHODS AND MATERIALS Forty Morse taper implants with an AE surface as controls (C) or with an AE surface functionalized with BSF18 (BF) were placed in the mandibles of 10 beagles. Implants were analyzed after 2 and 4 weeks of healing. Implant stability quotient (ISQ) values were registered immediately after installation and prior to sacrifice. Samples were analyzed for bone-to-implant contact (BIC) and bone density (BD). The characterization of BF implants included surface roughness analysis with atomic force microscopy and contact angle (CA) analysis to evaluate wettability. Data were analyzed using two-way ANOVA followed by Tukey's test (p < 0.05).

RESULTS:

Surface roughness was not affected by BF treatment. CA was lower in the BF group compared to the C group. No significant difference was observed in ISQ values between surfaces (p = 0,231), irrespective of time. Significantly higher ISQ values were observed for both implants after 4 weeks when compared with baseline (p = 0.04). Significantly higher BIC (p = 0.011) and BD (p = 0.025) values were observed for the BF compared to the C group at 2 weeks. Significantly higher BIC (p = 0.030) and BD (p = 0.015) values for the C group were observed at 4 weeks compared to 2 weeks. No significant difference was observed in the BF group between 2 and 4 weeks.

CONCLUSIONS:

Implant functionalization with BSF18 improved the wettability of the implant surface; enhancing BIC and BD at 2 weeks.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Clin Oral Implants Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil