Your browser doesn't support javascript.
loading
[The Effect of Intravenous Gamma-globulin Reagents on the Measurement Results of (1➔3)-ß-D-glucan].
Kansenshogaku Zasshi ; 91(1): 1-6, 2017 Jan.
Article em Ja | MEDLINE | ID: mdl-30277680
ABSTRACT
Serum (1→3) beta-D-glucan (BG) measurement is a useful test for systemic mycoses, and often used. On the other hand, various factors, including administration of intravenous immunoglobulins (IVIG) may cause false-positives. In the present study, we measured BG concentration of seven IVIG preparations with three lots respectively. BG levels varied with individual IVIG preparations (<3.0 - >300 pg/mL), and contamination from manufacturing processes was suspected. With serum BG concentration of clinical specimens obtained in Niigata University Medical & Dental Hospital, the difference between before and after administration of IVIG were calculated. The false-positive rate of BG due to IVIG administration was 9.8 %, and the positive predective value was reduced to 37.5%. Above all, administration of IVIG can complicate the BG test's interpretation, and caution is required.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gama-Globulinas / Beta-Glucanas Limite: Aged / Female / Humans / Male / Middle aged Idioma: Ja Revista: Kansenshogaku Zasshi Ano de publicação: 2017 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gama-Globulinas / Beta-Glucanas Limite: Aged / Female / Humans / Male / Middle aged Idioma: Ja Revista: Kansenshogaku Zasshi Ano de publicação: 2017 Tipo de documento: Article