Your browser doesn't support javascript.
loading
Contrast-Enhanced Magnetic Resonance Angiography Using a Novel Elastin-Specific Molecular Probe in an Experimental Animal Model.
Reimann, Carolin; Brangsch, Julia; Kaufmann, Jan Ole; Adams, Lisa C; Onthank, David C; Robinson, Simon P; Botnar, Rene M; Collettini, Federico; Makowski, Marcus R.
Afiliação
  • Reimann C; Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
  • Brangsch J; Department of Veterinary Medicine, Institute of Animal Welfare, Animal Behavior and Laboratory Animal Science, Freie Universität Berlin, Königsweg 67, Building 21, 14163 Berlin, Germany.
  • Kaufmann JO; Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
  • Adams LC; Department of Veterinary Medicine, Institute of Animal Welfare, Animal Behavior and Laboratory Animal Science, Freie Universität Berlin, Königsweg 67, Building 21, 14163 Berlin, Germany.
  • Onthank DC; Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
  • Robinson SP; Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
  • Botnar RM; Lantheus Medical Imaging, North Billerica, MA, USA.
  • Collettini F; Lantheus Medical Imaging, North Billerica, MA, USA.
  • Makowski MR; King's College London, School of Biomedical Engineering and Imaging Sciences United Kingdom, St Thomas' Hospital, Westminster Bridge Road, London SE1 7EH, UK.
Contrast Media Mol Imaging ; 2018: 9217456, 2018.
Article em En | MEDLINE | ID: mdl-30425609
ABSTRACT

Objectives:

The aim of this study was to test the potential of a new elastin-specific molecular agent for the performance of contrast-enhanced first-pass and 3D magnetic resonance angiography (MRA), compared to a clinically used extravascular contrast agent (gadobutrol) and based on clinical MR sequences. Materials and

Methods:

Eight C57BL/6J mice (BL6, male, aged 10 weeks) underwent a contrast-enhanced first-pass and 3D MR angiography (MRA) of the aorta and its main branches. All examinations were on a clinical 3 Tesla MR system (Siemens Healthcare, Erlangen, Germany). The clinical dose of 0.1 mmol/kg was administered in both probes. First, a time-resolved MRA (TWIST) was acquired during the first-pass to assess the arrival and washout of the contrast agent bolus. Subsequently, a high-resolution 3D MRA sequence (3D T1 FLASH) was acquired. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all sequences.

Results:

The elastin-specific MR probe and the extravascular imaging agent (gadobutrol) enable high-quality MR angiograms in all animals. During the first-pass, the probes demonstrated a comparable peak enhancement (300.6 ± 32.9 vs. 288.5 ± 33.1, p > 0.05). Following the bolus phase, both agents showed a comparable intravascular enhancement (SNR 106.7 ± 11 vs. 102.3 ± 5.3; CNR 64.5 ± 7.4 vs. 61.1 ± 7.2, p > 0.05). Both agents resulted in a high image quality with no statistical difference (p > 0.05).

Conclusion:

The novel elastin-specific molecular probe enables the performance of first-pass and late 3D MR angiography with an intravascular contrast enhancement and image quality comparable to a clinically used extravascular contrast agent.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Sondas Moleculares / Elastina / Angiografia por Ressonância Magnética / Meios de Contraste / Imageamento Tridimensional Limite: Animals Idioma: En Revista: Contrast Media Mol Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Sondas Moleculares / Elastina / Angiografia por Ressonância Magnética / Meios de Contraste / Imageamento Tridimensional Limite: Animals Idioma: En Revista: Contrast Media Mol Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha