Aptamer-DNA concatamer-quantum dots based electrochemical biosensing strategy for green and ultrasensitive detection of tumor cells via mercury-free anodic stripping voltammetry.
Zheng, Yue; Wang, Xiaoyu; He, Shengquan; Gao, Zehua; Di, Ya; Lu, Kunling; Li, Kun; Wang, Jidong.
Afiliação
  • Zheng Y; The First Hospital in Qinhuangdao Affiliated to Hebei Medical University, Qinhuangdao 066004, China. Electronic address: yuezheng1965@sina.com.
  • Wang X; Hebei Key Laboratory of Applied Chemistry, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • He S; Hebei Key Laboratory of Applied Chemistry, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Gao Z; Hebei Key Laboratory of Applied Chemistry, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Di Y; The First Hospital in Qinhuangdao Affiliated to Hebei Medical University, Qinhuangdao 066004, China.
  • Lu K; The First Hospital in Qinhuangdao Affiliated to Hebei Medical University, Qinhuangdao 066004, China.
  • Li K; Hebei Key Laboratory of Applied Chemistry, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Wang J; Hebei Key Laboratory of Applied Chemistry, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China. Electronic address: wangjidong@ysu.edu.cn.
Biosens Bioelectron ; 126: 261-268, 2019 Feb 01.
Article em En | MEDLINE | ID: mdl-30445301
ABSTRACT
A electrochemical biosensing strategy was developed for green and ultrasensitive detection of tumor cells by combining aptamer-DNA concatamer-CdTe quantum dots (QDs) signal amplification probe with mercury-free anodic stripping voltammetry (ASV). First, aptamer-DNA concatamer- CdTe QDs probes were designed by DNA hybridization and covalent assembling, which contained specific recognition of aptamer and signal amplification incorporating the DNA concatamer with QDs. Meanwhile, the capture electrode, glassy carbon electrode (GCE)/Graphene oxide (GO)/Polyaniline (PANI) / Glutaraldehyde (GA) / concanavalin A (Con A) was fabricated by a layer-by-layer assembling technique. K562 cells, as model cancer cells were detected to demonstrate the feasibility of this sensing strategy. Then, novel composite, graphene (GR)- Poly diallyldimethylammonium chloride (PDDA)/L-Cysteine (L- Cys), was explored in ASV which replaced mercury electrodes using for determination of tumor cells. The proposed electrochemical biosensor showed high sensitivity with the detection limit of 60 cells mL-1. More importantly, this novel design of signal amplification probes and the exploration of new composites in mercury-free ASV analysis would provide a promising method for ultrasensitive biosensor preparation and green electrochemical detection of tumor cells.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Técnicas Eletroquímicas / Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article