Your browser doesn't support javascript.
loading
Development and validation of HPLC method for the determination of Candesartan in human plasma.
Hamid, Shaista; Beg, Anwar Ejaz; Muhammad, Iyad Naeem; Hassan, Sohail; Hassan, Amir; Akram, Arfa; Alladin, Neyama.
Afiliação
  • Hamid S; Department of Pharmaceutics, Faculty of Pharmacy and Pharmaceutical Sciences, University of Karachi, Karachi, Pakistan.
  • Beg AE; Department of Pharmaceutics, Faculty of Pharmacy, Ziauddin University, Karachi, Pakistan.
  • Muhammad IN; Department of Pharmaceutics, Faculty of Pharmacy and Pharmaceutical Sciences, University of Karachi, Karachi, Pakistan.
  • Hassan S; Department of Pharmaceutical Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences, University of Karachi, Pakistan.
  • Hassan A; Department of Pharmaceutical Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences, University of Karachi, Pakistan.
  • Akram A; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, FUUAST, Karachi, Pakistan.
  • Alladin N; International Center for Chemical and Biological Sciences, University of Karachi, Karachi, Pakistan.
Pak J Pharm Sci ; 31(6): 2323-2327, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30473499
ABSTRACT
Candesartan (CAN), an ARB-blocker, antihypertensive, was analyzed in human plasma by a simple, accurate and precise RP-HPLC (reverse phase-High performance liquid chromatography assay method which was then validated for its accuracy, specificity and precision. The mobile phase has a constitution of acetone, diethylamine and distilled water, while Phosphoric acid was used to adjust the pH to 2.5±0.1. This mobile phase was run at 1.1ml/min and the fluorescence wavelength was set to 392 nm. A C-18 HPLC, column particle size (5 µm) Mediterranean Sea ® L x 1.D. 25cm x 4.6 mm (Supelcosil) , with auto sampler injection volume of 30µl ,an internal standard Valsartan was utilized for chromatographic detection. Candesartan took a retention time of 6±0.5 minutes. This method was validated by the parameters of selectivity, accuracy, precision, repeatability, reproducibility, recovery, linearity and stability. Candesartan's calibration curves were found to be linear in the range of 200ng/ml to 3.125ng/ml and the coefficient of determination (r2) was found to be 0.99. Analytical recovery obtained was above 88%. Hence, this method has been found to be useful for determining Candesartan in plasma.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetrazóis / Benzimidazóis / Cromatografia Líquida de Alta Pressão / Bloqueadores do Receptor Tipo 1 de Angiotensina II / Anti-Hipertensivos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Pak J Pharm Sci Assunto da revista: FARMACIA / FARMACOLOGIA / QUIMICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Paquistão
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetrazóis / Benzimidazóis / Cromatografia Líquida de Alta Pressão / Bloqueadores do Receptor Tipo 1 de Angiotensina II / Anti-Hipertensivos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Pak J Pharm Sci Assunto da revista: FARMACIA / FARMACOLOGIA / QUIMICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Paquistão