Your browser doesn't support javascript.
loading
Influence of albumin leakage on glycated albumin in patients with type 2 diabetes undergoing hemodialysis.
Ueda, Sayo; Nagai, Kojiro; Yokota, Narushi; Hirose, Daisuke; Mori, Hiroaki; Noma, Yoshihiko; Doi, Toshio; Minakuchi, Jun.
Afiliação
  • Ueda S; Department of Nephrology, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15, Kuramoto-cho, Tokushima, 770-8503, Japan.
  • Nagai K; Department of Nephrology, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15, Kuramoto-cho, Tokushima, 770-8503, Japan. knagai@tokushima-u.ac.jp.
  • Yokota N; Department of Kidney Disease (Dialysis and Transplantation), Kawashima Hospital, Tokushima, Japan.
  • Hirose D; Department of Kidney Disease (Dialysis and Transplantation), Kawashima Hospital, Tokushima, Japan.
  • Mori H; Department of Kidney Disease (Dialysis and Transplantation), Kawashima Hospital, Tokushima, Japan.
  • Noma Y; Department of Kidney Disease (Dialysis and Transplantation), Kawashima Hospital, Tokushima, Japan.
  • Doi T; Department of Nephrology, Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15, Kuramoto-cho, Tokushima, 770-8503, Japan.
  • Minakuchi J; Department of Kidney Disease (Dialysis and Transplantation), Kawashima Hospital, Tokushima, Japan.
J Artif Organs ; 22(3): 264-267, 2019 Sep.
Article em En | MEDLINE | ID: mdl-30805746
ABSTRACT
Glycated albumin (GA) is recommended as a better glycemic indicator than HbA1c in patients undergoing hemodialysis, because the red blood cell lifespan is generally faster than that in normal subjects. However, GA can be also affected by protein loss in urine and hemodialysis fluid. Therefore, in this study, we investigated the effect of albumin leakage induced by hemodialysis on GA. Nine patients undergoing hemodialysis with a large or small amount of albumin leakage were observed for 9 months in a crossover manner. As a result, it was shown that albumin leakage could affect GA, but the effect was practically small considering the prescription of diabetic drugs. The correlations between HbA1c and blood glucose levels and between GA and blood glucose levels were similar in our study. In conclusion, GA was a reliable indicator, even with the change of hemodialysis modality. The influence of albumin leakage induced by hemodialysis on GA was negligible practically. We should recognize that the preferable glycemic indicator in patients undergoing hemodialysis depends on the hemoglobin and albumin metabolism of each patient.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Albumina Sérica / Diálise Renal / Diabetes Mellitus Tipo 2 / Falência Renal Crônica Limite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Artif Organs Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Albumina Sérica / Diálise Renal / Diabetes Mellitus Tipo 2 / Falência Renal Crônica Limite: Aged / Humans / Male / Middle aged Idioma: En Revista: J Artif Organs Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão